Foxboro FBM233 Field Device System Integrator Module
FBM233 Field Device System Integrator Module

The FBM233 Redundant Field Device System Integrator (FDSI) module provides an Ethernet interface between single or dual-ported field I/O devices and the Foxboro Evo™ system. OVERVIEW Each FBM233 module has a single 10/100Mbps copper Ethernet connection and a single RJ-45 connector on the front of the module for connectivity to dual-ported Ethernet devices. The FBM233 is connected to Ethernet switches or hubs in order to communicate with one external device or up to 64 external devices. A pair of modules combine to provide redundancy at the Fieldbus Module (FBM) level. In this configuration, one FBM233 is the Master, and the other is the Tracker module. Input points on the control station are updated from the device inputs received on the network connected to the Master. Device output points, depending on the I/O driver, are written by both the Master and Tracker module. Role switching is automatic if problems are detected (for example, loss of heartbeat from any device) by the I/O driver, or the user can switch the roles at any time via SMDH. The general network configuration is shown in Figure 1.
Invensys Operations Management offers premiere feedwater control systems using the Foxboro® I/A Series® Distributed Control System (DCS). Recent implementations have offered operation philosophy enhancements, improved startup and runtime performance and significant reduction of unplanned unit trip outages. These advanced control techniques allow for less operator required interaction, more time of automatic control - including during start-up and shut-down when most unit trips are caused - making the entire control system more capable of handling process upset conditions along with normal operation.
FEATURES Key features of the FBM233 are: Redundant 10 Mbps or 100 Mbps Ethernet network transmission rate to/from field devices Communicates with up to 64 field devices I/O software driver is downloadable from a library of available protocols Up to 2000 DCI block connections Integrates field device data into a Foxboro Evo control database using Ethernet connectivity Field mounted Class G3 (harsh) environments.
FEM100
ZCP270
FCP270
FCM2F2
FCM2F4
FCM2F10
FBI100
FBI200A
FBI200
FBM201/b/c/d
FBM202
FMB203/b/c
FBM204
FBM206
FBM207/b/c
FBM208
FBM211
FBM212
FBM214b
FBM215
FBM216b
FBM217
FOXBORO C0162BX PCB ASSEMBLY
FOXBORO C119KY MOUNTING RELAY
FOXBORO C124KE ORIFICE
FOXBORO C141RX MOTOR PEN ASSEMBLY
FOXBORO CFT10-PAENFNS MASS FLOW TRANSMITTER
FOXBORO CM400YH INTERFACE MODULE FBM07 CONTACT DC INPUT
FOXBORO CM400YL I/O EXPANDER FBM10 120VAC
FOXBORO CM400YQ EXPANSION MODULE DC I/O
FOXBORO CM400YR I/O EXPANDER FBM15 120VAC
FOXBORO CM400ZA POWER MODULE 100-240VAC 100MS
FOXBORO CM902WL POWER MODULE INPUT SELECTABLE OUTPUT 39VDC
FOXBORO CM902WP POWER MODULE 4-24VDC
FOXBORO CM902WS POWER SUPPLY 120-240 VAC
FOXBORO CM902WV INDUSTRIAL POWER MODULE 9 - 24 VDC
FOXBORO CM902WX POWER MODULE AC/DC MEMORYIPM06A
FOXBORO CO136HZ RELAY
FOXBORO D0124ZX GALVO MOTOR 4-20 MA
FOXBORO D0130AX POWER REGULATOR DC PWA
FOXBORO D0134AB MEMORY BOARD
FOXBORO D0134AF POWER SUPPLY UNIVERSAL
FOXBORO D0134AN PC BOARD
FOXBORO D0134BU INTERFACE PCL1
FOXBORO D0134MP-T POWER SUPPLY 204 VA MULTI OUTPUT 5/12/15VDC NEMA1
FOXBORO D0134MQ POWER SUPPLY
FOXBORO D0134QN POWER SUPPLY
FOXBORO D0137AC VKF INTERFACE BOARD CRT 1 AND 2




Delivery:
Warranty:
All our products are covered by our own warranty.
Payment method:
Quick Quote: Receive price and availability today!
Replacing an electrical equipment unit in a plant is a complex task that requires careful planning and execution to ensure safety and minimize downtime. Here is a general step-by-step guide on how to replace electrical equipment in a plant:
Pre-Planning:
Safety Precautions:
Shutdown Procedures:
Disconnection:
Removal of Existing Equipment:
Installation of New Equipment:
Testing and Commissioning:
Documentation:
Training:
Startup:
Throughout the process, it’s important to work closely with a team that includes electrical engineers, technicians, and maintenance staff. Communication is key to a successful equipment replacement. Additionally, always adhere to local electrical codes and standards to ensure compliance and safety. If the task is beyond the expertise of in-house staff, consider hiring a professional contractor experienced in industrial electrical work.
Obtaining industrial automation programming software typically involves the following steps:
Identify Your Needs:
Research Software Options:
Contact Equipment Manufacturers:
Purchase or Download:
Academic or Evaluation Versions:
Open Source Options:
Licensing:
Training and Support:
Legal and Compliance:
Installation and Setup:
Here are some common ways to obtain industrial automation programming software:
Remember to keep your software updated to benefit from the latest features and security patches. Also, ensure that you have the necessary backup and recovery procedures in place to protect your programming work.
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.
COPYRIGHT© 2003-2025 Copyrighted
Phone(WeChat/Whatsapp)
+086-181 4410 0983
No 1134 Jimei North Road,
Hong Kong Office:
Guan Tang District, Hong Kong,