Brand:General Electric Model:IS215WERAH2B Series:Mark VIe Module Type:Communication Module Input Channels:27 Digital Inputs, 2 Analog Thermistor Temperature Sensor Inputs Output Channels:9 Relay Contact Outputs Board Size:Approximately 10.5 x 8.5 x 0.5 inches Weight:Approximately 1.2 lbs Connectivity:Ethernet/IP, DeviceNet, Profinet Operating Temperature Range:-20"C to +55"C Environmental Compliance:UL, CE, RoHS Operating Voltage:24V DC This high-performance PLC circuit board is specifically engineered to meet the stringent demands of industrial automation environments, providing exceptional control and precision. Featuring 27 digital inputs and 9 relay contact outputs, it enables precise control over various industrial processes, enhancing operational efficiency. The inclusion of 2 analog thermistor temperature sensors ensures accurate monitoring of environmental conditions, crucial for maintaining optimal performance in diverse industrial settings. Crafted from durable materials and equipped with advanced communication protocols, this circuit board seamlessly integrates into existing control systems, offering seamless connectivity and enhanced functionality. Easy to install and integrate, it requires minimal setup time, allowing for quick deployment in manufacturing lines, power plants, and other critical industrial operations. The GE IS215WERAH2B Printed Circuit Board is designed for high-performance industrial automation systems, ensuring reliable communication and control in demanding environments. In stock
Safety
specifications are generally applicable to control system handling.
Instructions and warnings related to a specific subject or operation of
the product.
The following norms must be strictly observed:
must strictly comply with the technical specifications and typical applications of the product system
Personnel training: Only trained personnel shall install, operate, maintain or repair the product system. must
Provide guidance and explanation of the situation in danger areas to these personnel.
Unauthorized changes: Changes or structural changes to the product system may not be made.
Maintenance responsibility: Must ensure that the product system is used
only under appropriate conditions and in full fitness for use.
Working environment: The user must meet the specified environmental conditions:
Safety regulation
The following safety provisions of EN 50110-1 shall be fully complied with when handling product systems (maintenance) :
1 Disconnect completely.
2 Secure to prevent reconnection.
3 Verify that the installation is complete.
4 Ground and short-circuit the device.
Warning:
Only qualified maintenance personnel can remove and insert the module.
In order to ensure the personal safety of the operator, before each
pulling out or inserting, you must
Disconnect the power supply and
ensure that there is no voltage on all terminals at the back, and the
product is effectively grounded with the ground screw at the back.
IS420YDASS1A processor
IS421UCSBS1A processor
IS421UCSCS2A processor
IS410TCDMS1A/2A Processor Terminal
IS420 UCSBH1A 600MHz processor
IS420 UCSBH3A 1200MHz processor
IS200TBCIS1C 24 discrete inputs (125 V dc, group isolated)
IS200TBCIS2C 24 discrete inputs (24 V dc, group isolated)
IS200TBCIS3C 24 discrete inputs (48 V dc, group isolated)
IS200STCIS1A, S2A 24 discrete inputs (24 V dc, group isolated)
IS200STCIS4A 24 discrete inputs (48 V dc, group isolated)
IS200STCIS6A 24 discrete inputs (125 V dc, group isolated)
IS200TRLYS1B 12 Form C mechanical relays w/ 6 solenoids, coil diagnostics
IS200TRLYS1D 6 Form A mechanical relays for solenoids, solenoid impedance diagnostics
Delivery:
Warranty:
All our products are covered by our own warranty.
Payment method:
Quick Quote: Receive price and availability today!
Replacing an electrical equipment unit in a plant is a complex task that requires careful planning and execution to ensure safety and minimize downtime. Here is a general step-by-step guide on how to replace electrical equipment in a plant:
Pre-Planning:
Safety Precautions:
Shutdown Procedures:
Disconnection:
Removal of Existing Equipment:
Installation of New Equipment:
Testing and Commissioning:
Documentation:
Training:
Startup:
Throughout the process, it’s important to work closely with a team that includes electrical engineers, technicians, and maintenance staff. Communication is key to a successful equipment replacement. Additionally, always adhere to local electrical codes and standards to ensure compliance and safety. If the task is beyond the expertise of in-house staff, consider hiring a professional contractor experienced in industrial electrical work.
Obtaining industrial automation programming software typically involves the following steps:
Identify Your Needs:
Research Software Options:
Contact Equipment Manufacturers:
Purchase or Download:
Academic or Evaluation Versions:
Open Source Options:
Licensing:
Training and Support:
Legal and Compliance:
Installation and Setup:
Here are some common ways to obtain industrial automation programming software:
Remember to keep your software updated to benefit from the latest features and security patches. Also, ensure that you have the necessary backup and recovery procedures in place to protect your programming work.
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.
COPYRIGHT© 2003-2024 Copyrighted
Phone(WeChat/Whatsapp)
+086-18144100983
No 1134 Jimei North Road, Jimei District
Hong Kong Office:
Guan Tang District, Hong Kong,