EMESRON FX-490 Positioning Servo Drive
EMESRON FX-490 Positioning Servo Drive
T
Model: FX‑490
Type: Integrated Brushless Positioning Servo Drive (amplifier + position controller built‑in)
Country of Origin: USA
Application: Indexing machinery, automated assembly, material handling, special‑purpose automation equipment
Certifications: UL, cUL, CE approved
Input Power: 200‑240 VAC, 50 / 60 Hz, single‑phase / three‑phase adaptable
DC Bus: 300 VDC nominal
Continuous Output Current: 9 A RMS
Peak Output Current: 18 A (max 2‑second duration)
PWM Switching Frequency: 16 kHz
Auxiliary Logic Supply: 2.4‑12 VDC, min 25 mA
Supported Feedback: Resolver (12‑bit, 4096 counts/rev); also compatible with encoder input
Angular Accuracy: ±20 arc‑minutes + 21600/SR
Velocity Accuracy: ±0.01 % of set speed
Command Inputs:
Torque command: ±10 VDC (10‑bit resolution)
Pulse‑train input: TTL level, max 210 kHz, min pulse width 1.5 ms
Motion Profiles: Linear profile, modified sine profile
Internal program steps: 100 steps base; expandable to 1024 steps with option module
Memory: Non‑volatile storage for up to 32 index parameter sets
Discrete Inputs: 8 points, 10‑30 VDC, sink/source configurable
Discrete Outputs: 4 points
Operation modes: Positioner mode, velocity mode, torque mode, pulse‑following mode
Serial Port: Opto‑isolated RS‑423 (compatible with RS‑232C / RS‑422)
Baud rate: 110 ~ 19200 baud
Multi‑drop: Daisy‑chain up to 31 drives on one serial link
Configuration software: PCXWin / PCX DOS tool software
Mounting: Panel chassis mount (cabinet‑mount)
Dimension (W × H × D): 155 mm × 320 mm × 50 mm
Net Weight: 0.74 kg
Protection Class: IP20 (only for cabinet interior installation)
Operating Ambient Temperature: 0 °C ~ +45 °C; derate torque 1 % / °C above 30 °C
Storage Temperature: −40 °C ~ +85 °C
Relative Humidity: 0‑95 % RH, non‑condensing
Built‑in protection: Over‑current, over‑voltage, over‑temperature, short‑circuit protection
| Shinkawa vm-5k dual vibration monitor meter vm-5g0-2 (Not Working) |
| Shinkawa UTC-1000 USP-25 Usp Tabla, 15138070 , Usado, Jap&6591 |
| SHINKAWA USP-09 PCB |
| FRP-341E board for shinkawa UTC-1000 |
| SHINKAWA IOP-57A board |
| Shinkawa CMU-13A Controller 100VAC only |
| Shinkawa FRP-338 (label: 04.05 FRX 400 AY 00) |
| Shinkawa UTC-1000 MDP-89 Board,22003196,Used,Jap+6592 |
| MDP-X MDP-94A for shinkawa UTC-1000 |
| SHINKAWA VM-721B/TB1 VIBRATION MONITORING SYSTEM CARD |
| SHINKAWA BH-164 & Yaskawa ULVI-A6-SWII & Mitutoyo ST133A |
| 1PCS NEW Shinkawa VK-452A1 position sensor DHL shipping |
| SHINKAWA VL-202A08L-1032 Proximity Sensor Vibration Probe Transducer |
| SHINKAWA VM 21B/TB1 VIBRATION MONITOR MODULE 2R05-004-P001A [FAST SHIPPING] |
| Shinkawa UTC-1000 ZUP-02C Board,Used,Jap&6590 |
| SHINKAWA VL-202A08L-1002 Probe Cable |
| Shinkawa UTC-1000 BCP-05 Platte, Gebraucht, Jap&6586 |
| ORIENTAL MOTOR 4GN9K / SHINKAWA MD-14A |
| Shinkawa FRP-208A (label: 94.11 FX20 CG 00) & FRP-206 wire bonder board |
| New VL-202A08L-1032 SHINKAWA Probe Sensor in stock |
| New SHINKAWA FL-202F08L-M2-00-08-10 Probe extension cable Fast shipping via |
| SHINKAWA FRP-184A FRP-111 PCB |
| Shinkawa RiverNew Vibratiuon Transducer Type VK202A2 (FREE SHIPPING) |
| MDP-Z MDP-86A for shinkawa UTC-1000 |
| 1pc FL-202F08L-M2-02-09-10 Shinkawa NEW Fast shipping DHL/FedEX |
| SHINKAWA FL-202F08L-M2-09-15-10 Sensore Di Vibrazioni #NEW |
| New SHINKAWA WW-142KL-4/NB1/CPT Probe extension cable DHL or fedex or UPS |
| Shinkawa EFU-45A02 Power Supply |
| SHINKAWA CMU-28A, Camera as photo, sn:4008, New missing box. |
| SHINKAWA VM-7 2R10-021-P001B PCB BOARD |
| New SHINKAWA PSP-30A Welding machine control board Fast Shipping FedEx or DHL |
| YASKAWA Used UGRME-01SSW11 , SHINKAWA MD-06 Cable damaged MOT-I-1045=2J41-2 |
| SHINKAWA VL-202A08L-1032 Proximity Sensor Vibration Probe Transducer |
| SHINKAWA IOP-119 PCB |




Delivery:
Warranty:
All our products are covered by our own warranty.
Payment method:
Quick Quote: Receive price and availability today!
Replacing an electrical equipment unit in a plant is a complex task that requires careful planning and execution to ensure safety and minimize downtime. Here is a general step-by-step guide on how to replace electrical equipment in a plant:
Pre-Planning:
Safety Precautions:
Shutdown Procedures:
Disconnection:
Removal of Existing Equipment:
Installation of New Equipment:
Testing and Commissioning:
Documentation:
Training:
Startup:
Throughout the process, it’s important to work closely with a team that includes electrical engineers, technicians, and maintenance staff. Communication is key to a successful equipment replacement. Additionally, always adhere to local electrical codes and standards to ensure compliance and safety. If the task is beyond the expertise of in-house staff, consider hiring a professional contractor experienced in industrial electrical work.
Obtaining industrial automation programming software typically involves the following steps:
Identify Your Needs:
Research Software Options:
Contact Equipment Manufacturers:
Purchase or Download:
Academic or Evaluation Versions:
Open Source Options:
Licensing:
Training and Support:
Legal and Compliance:
Installation and Setup:
Here are some common ways to obtain industrial automation programming software:
Remember to keep your software updated to benefit from the latest features and security patches. Also, ensure that you have the necessary backup and recovery procedures in place to protect your programming work.
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.
COPYRIGHT© 2003-2026 Copyrighted
Phone(WeChat/Whatsapp)
+086-181 4410 0983
No 1134 Jimei North Road,
Hong Kong Office:
Guan Tang District, Hong Kong,