REG670 IED (Intelligent Electronic Device) provides protection and monitoring for generators, prime movers, and step-up transformers in hydro, pump-storage, gas, combined cycle, steam, and cogeneration stations. With excellent performance, flexibility, and scalability it fulfills the demanding requirements, in every corner of the world, for both new installations and retrofits.
Based on Hitachi Energy's extensive experience, REG670 takes generator protection to a new performance level. Up to 24 analog inputs permit integration of main and back-up protection in one IED. Alternatively, additional objects, such as transformers, can be included in the generator protection scope. This enables full duplication of the protection in main one and main two. These features allow a reduction of the number of IEDs needed to protect the entire generating station, increasing availability at the same time. This, in turn, simplifies the installation and reduces its lifecycle cost as related to commissioning, maintenance, and spare parts. REG670 functionality also incorporates intelligent fault criteria, ensuring unrivaled selectivity and sensitivity.
Using an advanced and innovative filtering technique, REG670 can also provide integrated sub-synchronous resonance protection for turbo generators.
A generator protection scheme with REG670 meets the requirements for maximum dependability and availability. The generator differential protection features extremely fast detection criteria, with a typical operation time of 15 ms; while maintaining high security.
Among the many available functions, REG670 can include injection-based 100% stator and rotor earth-fault protection as well as 3rd harmonic based 100% stator earth-fault protection. These solutions enable a new way to optimize the cost-performance ratio of the protection system in relation to the importance or size of the generating station. Hitachi Energy's innovative implementation of the injection principle allows injection via a neutral point VT or even via an open-delta VT located at the generator terminals. As no changes need to be made in the primary circuit or in the grounding resistor, the design, installation, and commissioning of the protection system are easy and fast. The 3rd harmonic based 100% stator earth-fault protection utilizes the differential principle, which provides high sensitivity and security. This ensures correct operation even during low load conditions.
ABB RC-EH300/415 SK829007-B
ABB RDCU-02C 64607901 Inverter accessory control unit
ABB RDCU-12C 64672606 Inverter accessory control unit
ABB REF542PLUS integrated protection relay
ABB REF542PLUS with a host integrated protection relay
ABB REF601 BA426BA1XE feeder protection and monitoring device
ABB REF601 CE446BB1NH feeder protection and monitoring device
ABB REF610 Integrated Protection Relay
ABB REF610 C11LCLR 60HZ Integrated Protection Relay
ABB REF615C-D integrated protection relay feeder protection and monitoring device
ABB REF615E-D Integrated Protection Relay
ABB REF615E-E Integrated Protection Relay
ABB REF615 (requires order number) Integrated protection relay
ABB REM615 HCMJEAADABC2BNN11E Motor Integrated Protection Relay
ABB REP GOP2 control panel interface
ABB RET650 Integrated Protection Relay
ABB RET670 1MRK004816-AC Transformer Protection Integrated Protection Relay
ABB REX010 Transformer Unit
ABB REX011 Transformer Unit
Delivery:
Warranty:
All our products are covered by our own warranty.
Payment method:
Quick Quote: Receive price and availability today!
Replacing an electrical equipment unit in a plant is a complex task that requires careful planning and execution to ensure safety and minimize downtime. Here is a general step-by-step guide on how to replace electrical equipment in a plant:
Pre-Planning:
Safety Precautions:
Shutdown Procedures:
Disconnection:
Removal of Existing Equipment:
Installation of New Equipment:
Testing and Commissioning:
Documentation:
Training:
Startup:
Throughout the process, it’s important to work closely with a team that includes electrical engineers, technicians, and maintenance staff. Communication is key to a successful equipment replacement. Additionally, always adhere to local electrical codes and standards to ensure compliance and safety. If the task is beyond the expertise of in-house staff, consider hiring a professional contractor experienced in industrial electrical work.
Obtaining industrial automation programming software typically involves the following steps:
Identify Your Needs:
Research Software Options:
Contact Equipment Manufacturers:
Purchase or Download:
Academic or Evaluation Versions:
Open Source Options:
Licensing:
Training and Support:
Legal and Compliance:
Installation and Setup:
Here are some common ways to obtain industrial automation programming software:
Remember to keep your software updated to benefit from the latest features and security patches. Also, ensure that you have the necessary backup and recovery procedures in place to protect your programming work.
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.
COPYRIGHT© 2003-2024 Copyrighted
Phone(WeChat/Whatsapp)
+086-18144100983
No 1134 Jimei North Road, Jimei District
Hong Kong Office:
Guan Tang District, Hong Kong,