IC695CRU320 1Ghz CPU with 64Meg of memory 2 SERIAL PORTS
IC695CRH001 9070 MDL252 TO RX3I MDL241 HARNESS ASM
There are three models of embedded baseplates, the 311, 313, and 323. These model
numbers are based upon the CPU type that each contains. This chapter discusses only
the baseplate features of these products. CPU specifications for the embedded CPU are
located in Chapter 4. The embedded CPU baseplates have the following features:
The CPU type cannot be changed.
They do not support the use of expansion or remote racks, so these racks do
not have an expansion connector like the modular CPU baseplates do.
The models 311 and 313 are 5-slot baseplates, and the model 323 is a 10-slot
baseplate.
Since they do not require a plug-in CPU module, all numbered slots,
including Slot 1, can be used for I/O or Option modules.
The memory back-up battery is located in the Power Supply module; so if
the Power Supply is unplugged from the baseplate, the battery will be
disconnected from the memory circuits, which are located on the backplane
circuit board. However, the backplane circuit board contains a high value
capacitor, sometimes called a ”super capacitor,” that can store enough charge
to maintain the memory circuits for about 1 hour if the Power Supply is
removed or its battery is disconnected. Chapter 6 discusses the
IC693ACC315 Battery Accessory kit that can be used to maintain memory
contents when the Power Supply is removed from an embedded CPU
baseplate.
There are no configuration switches or jumpers on the Model 311, 313, or
323 baseplates.
An embedded CPU baseplate is always assigned, by default, Rack Number
Zero (0).
A Power Supply module must be plugged into the left slot (which is not
numbered) of these baseplates. The left slot is a unique size and type that
only supports a Power Supply module.
A CPU module (or a special Option module) must be installed in Slot 1 of
these baseplates. Slot 1 is a unique size and type that only supports a CPU
module or a special Option module like the FIP Remote I/O Scanner
(IC693BEM330). Slot 1 is labeled CPU/1.
Slots numbered 2 and above are of a unique size and type that only
supports I/O or Option modules.
Expansion and Remote baseplates are supported, so a 25-pin D-type female
expansion connector is located at the right end of the baseplate for
connecting to an Expansion or Remote baseplate.
Since the CPU is modular, it can be replaced or changed to a different type if
additional features are desired.
Only one CPU baseplate is allowed per system. If more than one baseplate
is used in a system, the additional ones must be either Expansion or Remote
types.
A modular CPU baseplate is always assigned, by default, Rack Number 0.
The Series 90-30 I/O modules described in this manual can be controlled two ways:
1. With a Series 90-30 Programmable Logic Controller (PLC).
2. With a Personal Computer (PC) that has an installed Personal Computer Interface card (or
similar interface). This allows software on the PC to control and monitor Series 90-30 I/O.
If you are using Series 90-30 I/O as part of a Series 90-30 PLC system, you should refer to
GFK-0356, the Series 90-30 Programmable Controller Installation manual, for more information.
If you are using a Personal Computer to control the Series 90-30 I/O, refer to the documentation
for the PCIF, your Personal Computer, and your application software for more information.
In addition to Series 90-30 I/O modules, the I/O system supports a wide variety of option
modules, such as
Genius Communications and Bus Controller
Communications Control module (for serial communications)
Programmable Coprocessor Modules and Alphanumeric Display Coprocessor
Motion control and High Speed Counter modules
Ethernet interface,
Various bus controllers.
State Logic modules
-----------------------------
IC695CRH001 9070 MDL252 TO RX3I MDL241 HARNESS ASM
IC695CRH002 9070 MDL253 TO RX3I MDL241 HARNESS ASM
IC695CRH003 9070 MDL250 TO RX3I MDL260 HARNESS ASM
IC695CRH004 9070 MDL240 TO RX3I MDL250 HARNESS ASM
IC695CRH006 9070 MDL251TO RX3i MDL250 Harness Asm
IC695CRH007 9070 MDL241 TO RX3I MDL231 HARNESS ASM
IC695CRH008 9070 MDL653 TO RX3I MDL660 HARNESS ASM
IC695CRH009 9070 MDL652 TO RX3I MDL654 HARNESS ASM
IC695CRH010 9070 MDL654 TO RX3I MDL658 HARNESS ASM
IC695CRH011 9070 MDL640 TO RX3I MDL632 HARNESS ASM
IC695CRH012 9070 MDL651 TO RX3I MDL654 HARNESS ASM
IC695CRH013 9070 MDL671 TO RX3I MDL645 HARNESS ASM
IC695CRH014 9070 MDL350 TO RX3I MDL340 HARNESS ASM
IC695CRH015 9070 MDL340 TO RX3I MDL330 HARNESS ASM
IC695CRH016 9070 MDL340 TO RX3I MDL350 HARNESS ASM
IC695CRH017 9070 MDL341 TO RX3I MDL350 HARNESS ASM
IC695CRH018 9070 MDL341 TO RX3I MDL390 HARNESS ASM
IC695CRH019 9070 MDL752 TO RX3I MDL753 HARNESS ASM
IC695CRH020 9070 MDL750 TO RX3I MDL753 HARNESS ASM
IC695CRH021 9070 MDL940 TO RX3I MDL931 OR 940 HRNASM
IC695CRH022 9070 MDL940 TO RX3I MDL916 HARNESS ASM
IC695CRH023 9070 ALG230 TO RX3I ALG616 HARNESS ASM
IC695CRH024 9070 ALG230 TO RX3I ALG220 HARNESS ASM
IC695CRH025 9070 ALG230 TO RX3I ALG221 HARNESS ASM
IC695CRH026 9070 ALG230 TO RX3I ALG222 HARNESS ASM
IC695CRH027 9070 ALG230 TO RX3I ALG232 HARNESS ASM
IC695CRH028 9070 ALG440 TO RX3I ALG616 HARNESS ASM
IC695CRH029 9070 ALG440 TO RX3I ALG220 HARNESS ASM
IC695CRH030 9070 ALG440 TO RX3I ALG221 HARNESS ASM
IC695CRH031 9070 ALG441 TO RX3I ALG616 HARNESS ASM
IC695CRH032 9070 ALG441 TO RX3I ALG220 HARNESS ASM
IC695CRH033 9070 ALG441 TO RX3I ALG222 HARNESS ASM
IC695CRH034 9070 ALG441 TO RX3I ALG232 HARNESS ASM
IC695CRH035 9070 ALG320 TO RX3I ALG708 HARNESS ASM
IC695CRH036 9070 ALG320 TO RX3I ALG390 HARNESS ASM
IC695CRH037 9070 ALG320 TO RX3I ALG391 HARNESS ASM
IC695CRH038 9070 MDL740 to RX3i MDL765 Harness ASM
IC695CRH039 9070 MDL753 to RX3i MDL765 Harness ASM
IC695CRU320 1Ghz CPU with 64Meg of memory 2 SERIAL PORTS (occupies two slots on system base) redundant CPU. External high capacity battery IC693ACC302 required. The CRU320 supports both Genius LAN and Ethernet LAN. Dual Genius LAN is supported by an applicati
IC695CRU320CA Conformal coated. 1Ghz CPU with 64Meg of memory 2 SERIAL PORTS (occupies two slots on system base) redundant CPU. External high capacity battery IC693ACC302 required. The CRU320 will only work with RX3i ENIU remote I/O and Genius LAN.
IC695CRU320QP QuadPAC redundant controller. 1Ghz CPU with 64Meg of memory 2 SERIAL PORTS (occupies two slots on system base). External high capacity battery IC693ACC302 required.
IC695DEM004 Beta i Series 1-Axis Motion Demo Case for use with PACMotion or DSM324i motion controllers
IC695DEM006 PMM Demo Case: RX3i and PACMotion
IC695DEM008 Fieldbus Demo Case: RX3i and Fieldbus
IC695DEMP002 RX3i Demo Case - China
IC695ECM850 RX3i IEC61850 communication module
IC695ETM001 Ethernet module 10/100 Mbits 2 RJ45 connections one IP address occupies one slot on system base
IC695ETM001CA RX3i Ethernet Mdl,10/100Mbits,Conformal Coated.
IC695ETM001LT Low Temperature Tested (-40 to 60C) Ethernet module 10/100 Mbits 2 RJ45 connections one IP address occupies one slot on system base
IC695FTB001 FIBER OPTIC TERMINAL BOARD FOR PMM335
IC695FTB1B032 Fiber terminal Block kit includes the IC695FTB001 base plus two IC694TBS032 high density box style screw terminal blocks
IC695FTB1B132 Fiber terminal Block kit includes the IC695FTB001 base plus two IC694TBS032 high density extended shroud box style screw terminal blocks
IC695FTB1S032 Fiber terminal Block kit includes the IC695FTB001 base plus two IC694TBS032 high density spring style terminal blocks
IC695FTB1S132 Fiber terminal Block kit includes the IC695FTB001 base plus two IC694TBS032 high density extended shroud spring style terminal blocks
IC695GCG001 RX3i GENIUS Communications Gateway
IC695HSC304 RX3i High Speed Counter, 4 channels. 8 configurable inputs and 7 configurable ESCP outputs. Module supports high speed counting, input interrupts and programmable limit switch.
IC695HSC308 RX3i High Speed Counter, 8 channels. 16 configurable inputs and 14 configurable outputs. Supports high speed counting, interrupts and programmable limit switch. Module requires PCI bus with terminal block IC694TBxx32E (E) revision and above.
IC695LRE001 RX3i Local Expansion Module Occupies no system slots on base
IC695LRE001CA RX3i Local Serial Expansion Conformal Coated.
IC695MDL664 Smart Digital 24VDC Input module, 16 input channels in two groups of eight. Module does not ship with terminal block. IC694TBB032 or IC694TBSx032 terminal block is required.
IC695MDL664CA Conformal Coated. Smart Digital 24VDC Input module, 16 input channels in two groups of eight. Module does not ship with terminal block. IC694TBB032 or IC694TBSx032 terminal block is required.
IC695MDL765 Smart Digital Output Module 24/125 volt DC, ESCP 1A Positive Logic 16 Points. Module does not ship with terminal block. IC694TBB032 or IC694TBSx032 terminal block is required.
IC695MDL765CA Conformal Coated. Smart Digital Output Module 24/125 volt DC, ESCP 1A Positive Logic 16 Points. Module does not ship with terminal block. IC694TBB032 or IC694TBSx032 terminal block is required.
Delivery:
Warranty:
All our products are covered by our own warranty.
Payment method:
Quick Quote: Receive price and availability today!
Replacing an electrical equipment unit in a plant is a complex task that requires careful planning and execution to ensure safety and minimize downtime. Here is a general step-by-step guide on how to replace electrical equipment in a plant:
Pre-Planning:
Safety Precautions:
Shutdown Procedures:
Disconnection:
Removal of Existing Equipment:
Installation of New Equipment:
Testing and Commissioning:
Documentation:
Training:
Startup:
Throughout the process, it’s important to work closely with a team that includes electrical engineers, technicians, and maintenance staff. Communication is key to a successful equipment replacement. Additionally, always adhere to local electrical codes and standards to ensure compliance and safety. If the task is beyond the expertise of in-house staff, consider hiring a professional contractor experienced in industrial electrical work.
Obtaining industrial automation programming software typically involves the following steps:
Identify Your Needs:
Research Software Options:
Contact Equipment Manufacturers:
Purchase or Download:
Academic or Evaluation Versions:
Open Source Options:
Licensing:
Training and Support:
Legal and Compliance:
Installation and Setup:
Here are some common ways to obtain industrial automation programming software:
Remember to keep your software updated to benefit from the latest features and security patches. Also, ensure that you have the necessary backup and recovery procedures in place to protect your programming work.
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.
COPYRIGHT© 2003-2024 Copyrighted
Phone(WeChat/Whatsapp)
+086-18144100983
No 1134 Jimei North Road, Jimei District
Hong Kong Office:
Guan Tang District, Hong Kong,