1746-FIO4V module Rockwell SLC analog combination
Follow these steps to install the module: ATTENTION: Never install, remove, or wire modules with power applied to chassis. IMPORTANT The first slot of the chassis is reserved for the processor or the 1747-ASB module. Slot 1 A B D C Max 2 mm2 (14 AWG) Max 2 wires per terminal Max torque: 0.9 Nm (8 lb-in.) 1. Disconnect power. 2. Align the circuit board of module with the chassis card guide. (A) 3. Slide the module into the chassis until the bottom tabs lock into place. (B) 4. Route the wires down and away from the module, securing them with the wire tie. (C) 5. Cover all unused slots with Card Slot Filler, catalog number 1746-N2, to keep the chassis free from debris. 6. To remove the module, press and hold the module release located on each self-locking tab, and slide the module out of the chassis slot. (D)
The following modules are North American Hazardous Location approved: 1746-IA4, 1746-IA8, 1746-IA16, 1746-IB8, 1746-IB16, 1746-IC16, 1746-IG16, 1746-IH16, 1746-IM4, 1746-IM8, 1746-IM16, 1746-IN16, 1746-ITB16, 1746-ITV16, 1746-IV8, 1746-IV16, 1746-OA8, 1746-OA16, 1746-OAP12, 1746-OB8, 1746-OB6EI, 1746-OB16, 1746-OB16E, 1746-OBP8, 1746-OBP16, 1746-OG16, 1746-OV8, 1746-OV16, 1746-OVP16, 1746-OW4, 1746-OW8, 1746-OW16, 1746-OX8, 1746-IO4, 1746-IO8, 1746-IO12, 1746-IO12DC
1747-ACN15 Module Rockwell SLC ControlNet Adapter
1747-ACNR15 Module Rockwell SLC ControlNet Redundancy Adapter
1747-AENTR Module Rockwell SLC 500 Ethernet Adapter
1747-AIC Module Rockwell SLC Coupler
1747-ASB Module Rockwell SLC Combined Module
1747-BSN Module Rockwell SLC Backup Scan
1747-DCM Module Rockwell SLC Direct Communication
1747-DEMO-7 Module Rockwell SLC Demo Kit
1747-FC Module Rockwell SLC Ferrite Collar
1747-INTWINBAS Module Rockwell **Not Orderable Base Module**
1747-KE Module Rockwell SLC Communication Interface
1747-KFC15 Module Rockwell SLC Interface Module
1747-KY1 Module Rockwell SLC Processors Replacement Keys
1747-L511 Module Rockwell CPU Controller
1747-L514 Module Rockwell CPU Controller
1747-L524 Module Rockwell CPU Controller
1747-L531 Module Rockwell CPU Controller
1747-L532 Module Rockwell CPU Controller
1747-L533 Module Rockwell CPU Controller
1747-L541 Module Rockwell CPU Controller
1747-L542 Module Rockwell CPU Controller
1747-L543 Module Rockwell CPU Controller
1747-L551 Module Rockwell SLC Central Controller
1747-L552 Module Rockwell SLC Central Controller
1747-L553 Module Rockwell SLC Central Controller
1747-L553P Module Rockwell PRO-SET 200 Central Controller
1747-M1 Module Rockwell SLC Storage Unit
1747-M13 Module Rockwell SLC Storage Unit
1747-M15 Module Rockwell SLC Storage Unit Adaptor
1747-M2 Module Rockwell SLC Storage Unit
1747-M3 Module SVC Module Storage Unit
1747-SDN Module Rockwell SLC DeviceNet Scanner Module
1747-SN Module Rockwell SLC Remote 1/O Scan
1747-UIC Module Rockwell USB to DH-485 Download Cable
1747-UICC13 Module Rockwell SLC Cable
1747-WINBAS module SOF module SLC 500 base module
Delivery:
Warranty:
All our products are covered by our own warranty.
Payment method:
Quick Quote: Receive price and availability today!
Replacing an electrical equipment unit in a plant is a complex task that requires careful planning and execution to ensure safety and minimize downtime. Here is a general step-by-step guide on how to replace electrical equipment in a plant:
Pre-Planning:
Safety Precautions:
Shutdown Procedures:
Disconnection:
Removal of Existing Equipment:
Installation of New Equipment:
Testing and Commissioning:
Documentation:
Training:
Startup:
Throughout the process, it’s important to work closely with a team that includes electrical engineers, technicians, and maintenance staff. Communication is key to a successful equipment replacement. Additionally, always adhere to local electrical codes and standards to ensure compliance and safety. If the task is beyond the expertise of in-house staff, consider hiring a professional contractor experienced in industrial electrical work.
Obtaining industrial automation programming software typically involves the following steps:
Identify Your Needs:
Research Software Options:
Contact Equipment Manufacturers:
Purchase or Download:
Academic or Evaluation Versions:
Open Source Options:
Licensing:
Training and Support:
Legal and Compliance:
Installation and Setup:
Here are some common ways to obtain industrial automation programming software:
Remember to keep your software updated to benefit from the latest features and security patches. Also, ensure that you have the necessary backup and recovery procedures in place to protect your programming work.
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.
COPYRIGHT© 2003-2024 Copyrighted
Phone(WeChat/Whatsapp)
+086-18144100983
No 1134 Jimei North Road, Jimei District
Hong Kong Office:
Guan Tang District, Hong Kong,