Trusted® 8000 ICS T8270
T8270 Trusted Fan Tray (Chassis)
This document provides general information for the Trusted® Processor Interface Adapter T812X. The Adapter provides easy access to the communications ports of the Trusted Triple Modular Redundant (TMR) Processor (T8110B & T8111) in the Controller Chassis for the Distributed Control System (DCS) and other links. The unit is also used to enable a number of extended facilities available on the Trusted TMR Processor including facilities for the reception of IRIG-B time synchronisation signals, enabling the use of Dual (‘enhanced’) Peer to Peer and enabling the Trusted System to become MODBUS Master.
The migration principles are identical for Regent (panel mount) and Regent +Plus (rack mount) because the internal circuitry is the same, as is the software. In this document, the term ‘Regent’ is used for both variants. The Regent processor chassis with processor and communications modules is replaced by a Trusted processor chassis with communications modules. The T8160 TMR Interface module (otherwise known as the Regent interface module, or RIM) bridges the triplicated Regent Safetybus into the Trusted Inter-Module Bus (IMB). The T8160 has a choice of two companion slot cables TC-320-01 and TC321-01. TC-320-01 ends in three connectors that fit the Regent chassis sockets. TC-321-01 ends in three connectors that fit the existing Safetybus cables. This allows a choice of running new cables to the first expander chassis or using the extra length of the existing cables. The Trusted processor chassis is 6U high but also needs a 2U T8270 fan tray mounted above it. It should not be located directly above bulk power supplies or other significant sources of heat, as air is drawn from underneath the chassis. A Trusted system requires one T8110B processor module (which contains three identical processors). The chassis also has a companion processor slot to allow faulty processors to be replaced. For a Trusted-Regent hybrid, one T8160 TMR interface module is required, and this is also fitted in a companion slot, taking two of the eight single width slots. To replace the three Regent communications modules, two Trusted T8151B communication interface modules are adequate. These each contain four high speed serial ports and also two Ethernet ports. They support Modbus (master and slave) and native Trusted peer networks, but will not support Regent Peer to Peer networks or the Regent Guarded Peer link. Modbus Master requires a T8122 or T8123 Processor interface adapter.
T8402 digital input dual 60 channels
T8403 Digital Input TMR 40 Channels
T8403CX Digital Input TMR 40 Channels, Non-RoHS
T8423 Digital input TMR 40 channels 120 Vdc
T8424 Digital Input TMR 40 Channels 120 Vac
T8425 Digital Input TMR 40 Channels 120Vdc
T8431|Analog Input TMR 40 Channels
T8431CX|Analog Input TMR 40ch, Non-RoHS
T8432|Analog Input Dual 60 Channels
Delivery:
Warranty:
All our products are covered by our own warranty.
Payment method:
Quick Quote: Receive price and availability today!
Replacing an electrical equipment unit in a plant is a complex task that requires careful planning and execution to ensure safety and minimize downtime. Here is a general step-by-step guide on how to replace electrical equipment in a plant:
Pre-Planning:
Safety Precautions:
Shutdown Procedures:
Disconnection:
Removal of Existing Equipment:
Installation of New Equipment:
Testing and Commissioning:
Documentation:
Training:
Startup:
Throughout the process, it’s important to work closely with a team that includes electrical engineers, technicians, and maintenance staff. Communication is key to a successful equipment replacement. Additionally, always adhere to local electrical codes and standards to ensure compliance and safety. If the task is beyond the expertise of in-house staff, consider hiring a professional contractor experienced in industrial electrical work.
Obtaining industrial automation programming software typically involves the following steps:
Identify Your Needs:
Research Software Options:
Contact Equipment Manufacturers:
Purchase or Download:
Academic or Evaluation Versions:
Open Source Options:
Licensing:
Training and Support:
Legal and Compliance:
Installation and Setup:
Here are some common ways to obtain industrial automation programming software:
Remember to keep your software updated to benefit from the latest features and security patches. Also, ensure that you have the necessary backup and recovery procedures in place to protect your programming work.
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.
COPYRIGHT© 2003-2024 Copyrighted
Phone(WeChat/Whatsapp)
+086-18144100983
No 1134 Jimei North Road, Jimei District
Hong Kong Office:
Guan Tang District, Hong Kong,