Triconex Analog Input TriPak HART 5354 5354S2
Triconex Analog Input TriPak HART 5354 5354S2
Analog Input Baseplate Kit, HART 2354
Triconex 4850 HART Multiplexer 1600106-001
Controller Features
The Trident controller is a state-of-the-art programmable logic and process controller that
provides a high level of system fault tolerance. To help ensure the highest possible system
integrity at all times, the Trident controller includes these features:
• Provides Triple Modular Redundant (TMR) architecture whereby each of three
identical system channels independently executes the control program, and specialized
hardware/software mechanisms “vote” all inputs and outputs.
• Withstands harsh industrial environments.
• Enables field installation and repair to be done at the module level while the controller
remains online. Replacing an I/O module does not disturb field wiring.
• Supports I/O modules (analog and digital) and an optional Communication Module
that interfaces with Modbus masters and slaves, other Triconex controllers in Peer-to-
Peer networks, and external host applications on Ethernet networks.
• Support for:
— 25 I/O baseplates maximum
— 416 AI points maximum (13 AI baseplates, 13 AI/DI baseplates, or any combination
that does not exceed 416 total AI or AI/DI points)
— 20 AO points maximum (5 baseplates)
— 640 DI points maximum (20 DI baseplates, 13 AI/DI baseplates, or any combination
that does not exceed 640 total DI points)
— 320 DO points maximum (20 baseplates)
— 30 PI points maximum (5 baseplates)
— 640 SRO points maximum (20 baseplates)
• Integrates the I/O module with the termination assembly.
• Executes control programs developed and debugged with TriStation™ 1131 software.
• Allows normal maintenance while the Trident controller is operating, without
disturbing the controlled process.
• Provides TriStation 1131 and Modbus communication from the Communications
Integration Module (CIM), Communication Module (CM), or Main Processor (MP).
• Provides a dedicated co-processor that controls the input and output modules to
reduce the workload of the MP. Each I/O module is supported by custom applicationspecific
integrated circuits (ASICs), which scan inputs and perform diagnostics to
detect hardware faults. Output module ASICs do the following:
— Supply information for voting of output data.
— Check I/O loop-back data from the output terminal for final validation of the
output state.
— Perform diagnostics to detect hardware and field-wiring problems.
• Provides integral online diagnostics with adaptive-repair capabilities.
• Supports hot-spare I/O modules for critical applications where prompt service may not
be possible.
• Provides integral support for redundant field and logic power sources.
System Configuration
Physically, a basic Trident controller consists of MPs, I/O modules, an optional CM (v2 or v3
systems) or CIM (v3 systems), the baseplates on which the modules are mounted, field wiring
connections, and a PC running the TriStation 1131 software. This section briefly describes these
components.
A typical Trident system is configured into one or more vertical I/O columns guided by DIN
rails and mounted on a sheet-metal panel. Trident modules are field-replaceable units
consisting of an electronic assembly housed in a metal spine. Each module has a protective
cover that helps ensure no components or circuits are exposed even when a module is removed
from the rail. Offset backplane connectors make it impossible to plug a module in upside down,
and keys on each module help prevent the insertion of modules into incorrect slots. The Trident
controller supports digital and analog input and output points, as well as pulse and
thermocouple inputs and multiple communication protocols.
Controller Configuration
A basic Trident system consists of one MP assembly, an optional CIM or CM assembly, and I/O
assemblies. Assemblies are configured into a system on a mounting plate using interconnect
assemblies, extenders, I/O bus cables, and I/O bus terminators. I/O modules communicate
with the MPs by means of a triplicated, RS-485, bi-directional communication bus, called the
I/O bus.
----------------------------------
| TRICONEX 3708E New DHL shipping |
| TRICONEX AO2481 #F11 |
| TRICONEX 4119A TRICONEX 4119A TRICONEX 4119A |
| 4119A TRICONEX ENHANED COMMUNCATION MODULE, 7400145-200 Rev C |
| TRICONEX 115 VAC/DC IGITAL INPUT 3501T |
| TRICONEX EICM 4119A ENHANCED INTELLIGENT COMMUNICATION MODULE EICM4119A |
| TRICONEX 9563-810F Via |
| NEW TRICONEX CM2201 Module 90day swarranty锛?by DHL or EMS 锛?Opens in a new window or tab |
| 1 Pc. New For Triconex RXM4201 Remote Fiber Optic Module Membrane Keypad |
| Triconex Tricon Communication Module TCM 4352AN 7400280-200N Rev C3 |
| Triconex 3636E Sortie Module Relais |
| TRICONEX 3721 New Input Card 3721 |
| triconex 8312 System power card Brand New Expedited Shipping |
| TRICONEX RO-3451 PLC Module Via |
| Triconex 3721 Different analysis input module Brand New |
| TRICONEX 9563-810 4000093-350 1x Via |
| TRICONEX MODULE DI3301 |
| TRICONEX TCMC PCBA 7400281-500CP REV C |
| New TRICONEX Terminal Panel Module 7400165-510 3000510-510 #F2 |
| Triconex Assembly MP3009 4351B 3721 3604E 8311 with 8111 Expansion Chassis |
| TRICONEX 8312 System power card TRICON NEW DHL/FedEx |
| 3604E TRICONEX 3604E Digital input unit control card New |
| Brand new with box Triconex 3700A Controller module |
| 100% Test TRICONEX 3721 |
| Triconex 3501TN 3601TN 8310N2 Analog I/O Main Processor Tricon Communication |
| TRICONEX 4210 Module DHL/FedEx |
| TRICONEX module AI3351 #F8 |
| Triconex EMP II 3005 MODULE,3000348-500H0,3000348 500G0,Triconex EMPII 3005,EB |
| 3000520-390 Triconex Invensys Contact Termination Board Box 24v dc Rev B 9662-6 |
| NEW TRICONEX 8312 MODULE |
| TRICONEX 4117 CPU Processor Unit Module 1X New Via |
| TRICONEX 03490240 Power Module Rack 8307A 24 V AC/DC |
| TRICONEX 40000206-540 PLC Module Via |
| TRICONEX 8312 TRICONEX 8312 MODULE |
| NEW TRICONEX 9563-810 Module /xjk |
| CEV65M-10323 Brand New Fast Shipping By DHL |
| TRICONEX AI 2351 7400210-010 Invensys Baseplate 1x Via |
| TRICONEX HCU3700/3703E Module |
| Triconex 3511 pulse input module Triconex 3511 |
| TRICONEX 8312 Power module TRICONEX 8312 8312 |
| Triconex 3603b Rev A 17 Modulo Hvdo 120vac 3:3 |
| NEW TRICONEX HCU3700/3703E Module |
| Brand new with box Triconex AO3481 Controller module AO3481 |
| TRICONEX 2402 module NEW |
| TRICONEX 8312 INVENSYS Power Module 1x New Via FEDEX/UPS/DHL |
| New Triconex 2551 Modules. *mq |
| TRICONEX TRICONEX 3502E RQANS1 |
| TRICONEX T8830 PLC Module Via |
| TRICONEX PI 3511 New Card PI3511 |
| NEW TRICONEX 2402 TRICONEX ORIGINAL MANUFACTURER USA FEB |
| TRICONEX TCMC PCBA 7400281-500C REV C |
| TRICONEX TCM 4351B ASSY TCM-B COPPER COMMUNICATION MODULE |
| TRICONEX 8312 PLC MODULE fast ship via /ups. |




Delivery:
Warranty:
All our products are covered by our own warranty.
Payment method:
Quick Quote: Receive price and availability today!
Replacing an electrical equipment unit in a plant is a complex task that requires careful planning and execution to ensure safety and minimize downtime. Here is a general step-by-step guide on how to replace electrical equipment in a plant:
Pre-Planning:
Safety Precautions:
Shutdown Procedures:
Disconnection:
Removal of Existing Equipment:
Installation of New Equipment:
Testing and Commissioning:
Documentation:
Training:
Startup:
Throughout the process, it’s important to work closely with a team that includes electrical engineers, technicians, and maintenance staff. Communication is key to a successful equipment replacement. Additionally, always adhere to local electrical codes and standards to ensure compliance and safety. If the task is beyond the expertise of in-house staff, consider hiring a professional contractor experienced in industrial electrical work.
Obtaining industrial automation programming software typically involves the following steps:
Identify Your Needs:
Research Software Options:
Contact Equipment Manufacturers:
Purchase or Download:
Academic or Evaluation Versions:
Open Source Options:
Licensing:
Training and Support:
Legal and Compliance:
Installation and Setup:
Here are some common ways to obtain industrial automation programming software:
Remember to keep your software updated to benefit from the latest features and security patches. Also, ensure that you have the necessary backup and recovery procedures in place to protect your programming work.
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.
COPYRIGHT© 2003-2025 Copyrighted
Phone(WeChat/Whatsapp)
+086-181 4410 0983
No 1134 Jimei North Road,
Hong Kong Office:
Guan Tang District, Hong Kong,