Triconex Digital Input TriPak, High Resolution, High Voltage 5312-F
Triconex Digital Input TriPak, High Resolution, High Voltage 5312-F
Digital Input Baseplate Kit, High Voltage 2302-F
Controller Features
The Trident controller is a state-of-the-art programmable logic and process controller that
provides a high level of system fault tolerance. To help ensure the highest possible system
integrity at all times, the Trident controller includes these features:
• Provides Triple Modular Redundant (TMR) architecture whereby each of three
identical system channels independently executes the control program, and specialized
hardware/software mechanisms “vote” all inputs and outputs.
• Withstands harsh industrial environments.
• Enables field installation and repair to be done at the module level while the controller
remains online. Replacing an I/O module does not disturb field wiring.
• Supports I/O modules (analog and digital) and an optional Communication Module
that interfaces with Modbus masters and slaves, other Triconex controllers in Peer-to-
Peer networks, and external host applications on Ethernet networks.
• Support for:
— 25 I/O baseplates maximum
— 416 AI points maximum (13 AI baseplates, 13 AI/DI baseplates, or any combination
that does not exceed 416 total AI or AI/DI points)
— 20 AO points maximum (5 baseplates)
— 640 DI points maximum (20 DI baseplates, 13 AI/DI baseplates, or any combination
that does not exceed 640 total DI points)
— 320 DO points maximum (20 baseplates)
— 30 PI points maximum (5 baseplates)
— 640 SRO points maximum (20 baseplates)
• Integrates the I/O module with the termination assembly.
• Executes control programs developed and debugged with TriStation™ 1131 software.
• Allows normal maintenance while the Trident controller is operating, without
disturbing the controlled process.
• Provides TriStation 1131 and Modbus communication from the Communications
Integration Module (CIM), Communication Module (CM), or Main Processor (MP).
• Provides a dedicated co-processor that controls the input and output modules to
reduce the workload of the MP. Each I/O module is supported by custom applicationspecific
integrated circuits (ASICs), which scan inputs and perform diagnostics to
detect hardware faults. Output module ASICs do the following:
— Supply information for voting of output data.
— Check I/O loop-back data from the output terminal for final validation of the
output state.
— Perform diagnostics to detect hardware and field-wiring problems.
• Provides integral online diagnostics with adaptive-repair capabilities.
• Supports hot-spare I/O modules for critical applications where prompt service may not
be possible.
• Provides integral support for redundant field and logic power sources.
System Configuration
Physically, a basic Trident controller consists of MPs, I/O modules, an optional CM (v2 or v3
systems) or CIM (v3 systems), the baseplates on which the modules are mounted, field wiring
connections, and a PC running the TriStation 1131 software. This section briefly describes these
components.
A typical Trident system is configured into one or more vertical I/O columns guided by DIN
rails and mounted on a sheet-metal panel. Trident modules are field-replaceable units
consisting of an electronic assembly housed in a metal spine. Each module has a protective
cover that helps ensure no components or circuits are exposed even when a module is removed
from the rail. Offset backplane connectors make it impossible to plug a module in upside down,
and keys on each module help prevent the insertion of modules into incorrect slots. The Trident
controller supports digital and analog input and output points, as well as pulse and
thermocouple inputs and multiple communication protocols.
Controller Configuration
A basic Trident system consists of one MP assembly, an optional CIM or CM assembly, and I/O
assemblies. Assemblies are configured into a system on a mounting plate using interconnect
assemblies, extenders, I/O bus cables, and I/O bus terminators. I/O modules communicate
with the MPs by means of a triplicated, RS-485, bi-directional communication bus, called the
I/O bus.
----------------------------------
| ALSTOM BATTERY ALARM 300, BA31251238A |
| NEW UNALSTOM EPIC II ELECTRICAL SOUTH KV METERING BOARD 1060218030KV |
| ALSTOM EPIC II V4550220-0100 UNMP |
| Alstom Micom P122 Power Protection Relay P122A00M111 |
| Alstom Emergency Response Team Green Hat |
| Alstom Motpro MCHNM01H1AB0500A MCHNM Protection Relay 173237 |
| Alstom D-984-057805 Intensity and Fault Detection Board |
| Surplus Raymond / Alstom Bowl Mill Grinding Roll Lock Nut 62-206 |
| MITRAC TCMS BY ALSTOM MIO-E 3EST000228-7048 Control Management System |
| ALSTOM MITRAC TCMS MIO-E 3EST000228-7043 Control & Management System |
| ALSTOM 3EST000214-1341 Modules DCA3100A |
| ALSTOM BATTERY ALARM 300, BA31251238A |
| New Sealed Alstom Railroad Signal Relay Flasher 48-54 flashes per minute 55085 |
| ALSTOM POWER CPB353C BODY NSNP |
| Alstom Power Boiler Superheater Spacer 1T-22073 NEW Lot of 27 pcs |
| GEC Alstom Quadramho SHPM 101 Static Distance Protection Relay |
| alstom electroblox model 241498-100 revb1 517a2 |
| Alstom Areva P141 P141218A2M0150C Feeder Protection Relay (As-Is) |
| GEC Alstom 23X2171BR Power Supply Board KCC8424 PCB KCC 8424 Circuit 23X2171 BRL |
| ALSTOM MICOM P743 GENERATOR PROTECTION NUMERICAL RELAY P743216A6M0510K |
| ALSTOM CEGELEC 20X4260/10A ,ALSPA 20X4260A1L,ABB EH100AP CURRENT SENSOR |
| ALSTOM MX3EG1A.12 Protection Relay |
| NEW ALSTOM MP/H3166/G01 LINEAR POWER SUPPLY MD/Z1003 MPH3166G01 |
| ALSTOM RA332 REASON REMOTE ACQUISITION UNIT RA332311D33AC |
| ALSTOM MVAAM11 DC SUPERVISION RELAY MVAAM11B1CJ5516A |
| ALSTOM POWER ZC115 HAMMER "NEW" Z115D FOR #51 IMP MILL (LOT OF 3 HAMMERS) |
| Alstom Emergency Response Team Green Hat |
| ALSTOM POWER 26020 SPRING NSNP |
| Alstom Micom P122 Power Protection Relay P122A00M111 |
| Alstom SPC160 Servo Motor Position Controller v2.1 B0043644 Unused |
| ALSTOM CIRCUIT BOARD CCS160 NEGTCCS160 FEG-S032-L001 XLNT TAKEOUT !! |
| Alstom 902-3144-9 Plain Pin .62 Dia SS x 1.0 Lg; 90231449 |
| ALSTOM POWER 01-22643 SPRING SEAT NSNP |
| MITRAC TCMS BY ALSTOM DCU2 3EST000216-9644 BOMBARDIER |
| ALSTOM POWER A96500103 HEATER NSNP |
| ALSTOM Reason MU320-3L5522BA02A - Integrated Analog and Digital Merging Unit |
| Alstom mvapm32d1aa2001a voltage balance relay 110vac 50hz |
| ALSTOM MOTPRO MCHNM PROTECTION RELAY MCHNM01H1AB0500A |
| Alstom Mae00-10 Rtd Termination Panel |
| Alstom gds1191-6011 pc board 20x4506/10d |
| ALSTOM POWER SC-2528 COVER PLATE FOR BEARING HOUSING |
| Alstom MRSU04 125v 5s |
| MICOM ALSTOM GE P14DB11A4C0620A NUMERICAL FEEDER PROTECTION RELAY |
| Alstom EPSD-0372-00 Pcb Circuit Board |
| NEW Alstom JOINT-1.5DIA-300#-90DEG-SWIVEL Air Preheater |
| Alstom UKK 94.105.659-04 94.105.182-11 Board |
| NEW Lot of 4 Alstom D297/1486P03 Flange Screws 9.65" L 1.45" Dia 1.87" Head W |
| NEW Lot of 4 Alstom D297/1500P05 Flange Screws 8.2" L 1.22" Dia 1.5" Head W |
| ALSTOM POWER INC SMRS1/65 GEAR WORM NSNP |
| Alstom Power HTGD333350P0049 Key Segment |
| Alstom D-984-0578 Intensity And Fault Detection Board |
| Alstom TUG 0110 / 03820042 Tropic Voltage Relay 110VDC |
| ALSTOM A09E04D 6442450946 PLUG STEM PROCONEX 1/2" by 12.5"L NEW USA SS New $99 |
| GE Alstom CEGELEC IC693PWR324R ALSPA 80-35 Power Supply |
| ALSTOM MMLG01 Conversion Module |
| @@ ALSTOM CAT # A62-122 B1 RELAY (GTN43) |
| Alstom Air Preheated Enclosed Gear Reducer Drive Ratio 104.93:1 Mod. 4AP Rebuilt |
| Alstom 56001-943-01 Slow Acting DC Relay 13 Amp 530 Ohm Coil |
| ALSTOM POWER 3A-3877A DOOR PASSAGEWAY UNMP |




Delivery:
Warranty:
All our products are covered by our own warranty.
Payment method:
Quick Quote: Receive price and availability today!
Replacing an electrical equipment unit in a plant is a complex task that requires careful planning and execution to ensure safety and minimize downtime. Here is a general step-by-step guide on how to replace electrical equipment in a plant:
Pre-Planning:
Safety Precautions:
Shutdown Procedures:
Disconnection:
Removal of Existing Equipment:
Installation of New Equipment:
Testing and Commissioning:
Documentation:
Training:
Startup:
Throughout the process, it’s important to work closely with a team that includes electrical engineers, technicians, and maintenance staff. Communication is key to a successful equipment replacement. Additionally, always adhere to local electrical codes and standards to ensure compliance and safety. If the task is beyond the expertise of in-house staff, consider hiring a professional contractor experienced in industrial electrical work.
Obtaining industrial automation programming software typically involves the following steps:
Identify Your Needs:
Research Software Options:
Contact Equipment Manufacturers:
Purchase or Download:
Academic or Evaluation Versions:
Open Source Options:
Licensing:
Training and Support:
Legal and Compliance:
Installation and Setup:
Here are some common ways to obtain industrial automation programming software:
Remember to keep your software updated to benefit from the latest features and security patches. Also, ensure that you have the necessary backup and recovery procedures in place to protect your programming work.
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.
COPYRIGHT© 2003-2025 Copyrighted
Phone(WeChat/Whatsapp)
+086-181 4410 0983
No 1134 Jimei North Road,
Hong Kong Office:
Guan Tang District, Hong Kong,