triconex Main Processor TriPak 5101
triconex Main Processor TriPak 5101
Main Processor Baseplate Kit 2101
Controller Features
The Trident controller is a state-of-the-art programmable logic and process controller that
provides a high level of system fault tolerance. To help ensure the highest possible system
integrity at all times, the Trident controller includes these features:
• Provides Triple Modular Redundant (TMR) architecture whereby each of three
identical system channels independently executes the control program, and specialized
hardware/software mechanisms “vote” all inputs and outputs.
• Withstands harsh industrial environments.
• Enables field installation and repair to be done at the module level while the controller
remains online. Replacing an I/O module does not disturb field wiring.
• Supports I/O modules (analog and digital) and an optional Communication Module
that interfaces with Modbus masters and slaves, other Triconex controllers in Peer-to-
Peer networks, and external host applications on Ethernet networks.
• Support for:
— 25 I/O baseplates maximum
— 416 AI points maximum (13 AI baseplates, 13 AI/DI baseplates, or any combination
that does not exceed 416 total AI or AI/DI points)
— 20 AO points maximum (5 baseplates)
— 640 DI points maximum (20 DI baseplates, 13 AI/DI baseplates, or any combination
that does not exceed 640 total DI points)
— 320 DO points maximum (20 baseplates)
— 30 PI points maximum (5 baseplates)
— 640 SRO points maximum (20 baseplates)
• Integrates the I/O module with the termination assembly.
• Executes control programs developed and debugged with TriStation™ 1131 software.
• Allows normal maintenance while the Trident controller is operating, without
disturbing the controlled process.
• Provides TriStation 1131 and Modbus communication from the Communications
Integration Module (CIM), Communication Module (CM), or Main Processor (MP).
• Provides a dedicated co-processor that controls the input and output modules to
reduce the workload of the MP. Each I/O module is supported by custom applicationspecific
integrated circuits (ASICs), which scan inputs and perform diagnostics to
detect hardware faults. Output module ASICs do the following:
— Supply information for voting of output data.
— Check I/O loop-back data from the output terminal for final validation of the
output state.
— Perform diagnostics to detect hardware and field-wiring problems.
• Provides integral online diagnostics with adaptive-repair capabilities.
• Supports hot-spare I/O modules for critical applications where prompt service may not
be possible.
• Provides integral support for redundant field and logic power sources.
System Configuration
Physically, a basic Trident controller consists of MPs, I/O modules, an optional CM (v2 or v3
systems) or CIM (v3 systems), the baseplates on which the modules are mounted, field wiring
connections, and a PC running the TriStation 1131 software. This section briefly describes these
components.
A typical Trident system is configured into one or more vertical I/O columns guided by DIN
rails and mounted on a sheet-metal panel. Trident modules are field-replaceable units
consisting of an electronic assembly housed in a metal spine. Each module has a protective
cover that helps ensure no components or circuits are exposed even when a module is removed
from the rail. Offset backplane connectors make it impossible to plug a module in upside down,
and keys on each module help prevent the insertion of modules into incorrect slots. The Trident
controller supports digital and analog input and output points, as well as pulse and
thermocouple inputs and multiple communication protocols.
Controller Configuration
A basic Trident system consists of one MP assembly, an optional CIM or CM assembly, and I/O
assemblies. Assemblies are configured into a system on a mounting plate using interconnect
assemblies, extenders, I/O bus cables, and I/O bus terminators. I/O modules communicate
with the MPs by means of a triplicated, RS-485, bi-directional communication bus, called the
I/O bus.
----------------------------------
| Triconex Cable Assembly 4000029-020 |
| Triconex Termination Panel for 2755 7400061-600 |
| TriConex SDO 3411 Output Module |
| 3604E Triconex Digital Output Modules 24VDC 16 Point TMR NEW SURPLUS |
| TRICONEX TCM 4351B ASSY TCM-B COPPER COMMUNICATION MODULE , 300787-120 Rev E |
| EMPII3006 | Triconex | Processor Module, 1-Port, LED Indicators, |
| TRICONEX 3700A / 3700A |
| Triconex Cable Assembly 4000042-120 |
| Triconex Cable Assembly 4000042-125 |
| Triconex 3700A Analog Input Module FOR PARTS OR REPAIR |
| Triconex Cable Assembly - 4000212-002 (Pack Of 2 Cables) |
| TRICONEX CM3201 Digital input unit control card Module |
| TRICONEX EXTENDER 7400213-100 REV:A2 |
| 1 pc TRICONEX MAIN PROCESSOR MODULE P/N MP3101 |
| Triconex Cable Assembly 4000043-120 |
| 3503E | Triconex | Digital Input Module Triconex 3503E 24VDC -New Box No Label |
| Triconex Terminal Panel for 2750-2 300012-220 |
| TriConex DI2301 Baseplate |
| Triconex Cable Assembly 4000056-006 |
| Triconex TCM 4351 Communication Module Internal Main Board (7400280-100 Rev C3) |
| Triconex 9662-6 / 3000520-390 Rev B Termination Board |
| TRICONEX 3601E DIGITAL OUTPUT |
| TriConex MP2101 Baseplate |
| Triconex Terminal Panel for 2652-5 7400058-350 |
| Triconex Cable Assembly 4000043-332 |
| TRICONEX 3503E / 3503E |
| TRICONEX 4119A / 4119A |
| TRICONEX 3503E / 3503E |
| TRICONEX 2750 / 2750 |
| TRICONEX 9651-110 |
| TriConex AI2351 Analog Input Baseplate |
| Triconex RXM 4200 Remote Fiber Optic Module |
| Triconex 8305 120VAC Power Supply Module 7400067-01 |
| Triconex 93-2817 Pcb Circuit Board |
| TRICONEX card module 7400209-010 |
| TRICONEX 3700A / 3700A |
| TRICONEX 2658 / 2658 |
| TRICONEX 4000212-020 / 4000212020 |
| Phoenix Contact 3000400-530 Triconex Terminal Block |
| Triconex 3701 Analog input module |
| Triconex 7400233-160 Terminal Block Assembly 115v-ac |
| TRICONEX 8310N2 120VAC/DC 8310N 8310 Power Module |
| Triconex | 3000290-380 | /Refurbished |
| Triconex Terminal Board for 2553 7400056-310 |
| TRICONEX 2651 / 2651 |
| TRICONEX 3700 / 3700 |
| TRICONEX 3708E / 3708E |
| TRICONEX 2553 / 2553 |
| Triconex Power Module 8300 120V AC/DC |
| Triconex Relay Outpout for 2658 74000110-010 |
| TRICONEX TSX E1 6218 / 6100329-001/ TSXE16218 |
| TRICONEX 3510 / 3510 |
| TRICONEX 3504E / 3504E |
| TRICONEX 7400213-100 Card Module Rev:A2 |
| TRICONEX 4000056-002 B Tested in Good condition Fast Ship |
| Triconex 3601T Digital Output Module 3000307-055 rev D |
| Triconex 3701 Analog input module #2 |
| Phoenix Contact 3000520-280 Triconex Terminal Block |
| Triconex 9563-8 / 3000510-380 Phoenix Contact Terminal Block |
| Triconex Terminal Board for 2551 7400058-110 |
| Invensys Triconex Cable 4000094-310 New |
| Triconex Cable Wire Assembly 4000056-006 B 5 Pin |
| TRICONEX 7400219-030 AO/DO BASEPLATE DO 2401H |
| TRICONEX 3805H ANALOG OUTPUT MODULE EAQ 3:3 0-22MA , 3000316-111 |
| Triconex 7400051-011 Processor Module |
| Triconex 7400050-010 Processor Module |
| Triconex 7400165-380 AI/DI Panel 7300165-001 Rev A/1 |
| Triconex/Phoenix Contact 7400143-530 Dido Panel 9853-6XX |
| TRICONEX AI/AO Hart Baseplate 7400307-010 |
| TRICONEX 8311 / 8311 |
| TRICONEX 7400165-390 / 7400165390 |
| TRICONEX 2553 / 2553 |
| CM2201(7400206-100) | Triconex | Communication Module, |
| TRICONEX 8305A / 8305A |
| TRICONEX 4119A EICM 7400145-100 REV B ENHANCED INTELLIGENT COMMUNICATION MODULE |
| Triconex 7400064-530 2705-3 Processor Module |
| Triconex 3625 , 3000791-020 Rev E 24VDC Digital Output Module |
| TRICONEX 7400210-020 AI BASEPLATE AI 2361 |
| Triconex Digital Relay Output 3636R |
| EICM4119A | Triconex | Communication Module, 5-Port, |
| TRICONEX 8111 / 8111 |
| TRICONEX EMPII MODULE 3006 NSNP |
| TRICONEX PHOENIX CONTACT 3000520-390 Termination Board 7400166-390 9662 |
| TRICONEX 3006 / 3006 |
| TRICONEX 4000016-015 / 4000016015 |
| Tri-Sen EDI 7400090-025 Triconex Rev D 2 24V AC/DC Digital Input 3503E Module |
| Triconex 9664-1XX Terminal Block Assembly 120v-ac/dc |
| 4000093-310 | Triconex | Cable Assembly, |
| & Tested TRICONEX DI3301 Digital Input Module |
| TRICONEX 3703E / 3703E |




Delivery:
Warranty:
All our products are covered by our own warranty.
Payment method:
Quick Quote: Receive price and availability today!
Replacing an electrical equipment unit in a plant is a complex task that requires careful planning and execution to ensure safety and minimize downtime. Here is a general step-by-step guide on how to replace electrical equipment in a plant:
Pre-Planning:
Safety Precautions:
Shutdown Procedures:
Disconnection:
Removal of Existing Equipment:
Installation of New Equipment:
Testing and Commissioning:
Documentation:
Training:
Startup:
Throughout the process, it’s important to work closely with a team that includes electrical engineers, technicians, and maintenance staff. Communication is key to a successful equipment replacement. Additionally, always adhere to local electrical codes and standards to ensure compliance and safety. If the task is beyond the expertise of in-house staff, consider hiring a professional contractor experienced in industrial electrical work.
Obtaining industrial automation programming software typically involves the following steps:
Identify Your Needs:
Research Software Options:
Contact Equipment Manufacturers:
Purchase or Download:
Academic or Evaluation Versions:
Open Source Options:
Licensing:
Training and Support:
Legal and Compliance:
Installation and Setup:
Here are some common ways to obtain industrial automation programming software:
Remember to keep your software updated to benefit from the latest features and security patches. Also, ensure that you have the necessary backup and recovery procedures in place to protect your programming work.
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.
COPYRIGHT© 2003-2025 Copyrighted
Phone(WeChat/Whatsapp)
+086-181 4410 0983
No 1134 Jimei North Road,
Hong Kong Office:
Guan Tang District, Hong Kong,