MOOG QAIO 2/2-AV I/O extension module D137-001-011
The QAIO 2/2 analog module is used for local extension
of the inputs and outputs (I/O) of the MSC I or MSC II
Motion Controller. The module is mounted on a DIN rail and
directly connected to an MSC I or MSC II Motion Controller
via the internal Extension bus (E-Bus).
The QAIO 2/2 has the following inputs and outputs:
• 2 analog inputs, each configurable in the Moog Axis
Control Software (MACS) development environment
as ±10 V, ±10 mA or 4 to 20 mA. The inputs are
converted in multiplex operation
• 1 reference voltage output: The reference voltage
source provides a short circuit protected voltage of
+10 V
• 2 analog outputs, each ±10 V, additionally individually
configurable in the MACS software as ±10 mA, ±50 mA
or 4 to20 mA with wire fault monitoring
• 1 pulse input 24 V useable as counter input or
frequency measurement input
On the front, 4 LEDs provide information about the status
of important module functions.
The configuration of the analog I/O is carried out per
software via the central control configuration in the MACS
development environment. Either the two analog inputs or
the pulse input can be used.
The I/O of the analog extension module is actuated
directly from an MSC I or MSC II Motion Controller via the
E-Bus. All input- and output-data is transferred within one
cycle of the E-Bus.
One MSC I or MSC II Motion Controller can be extended
with a maximum of 7 QAIO 2/2-AV modules. It is not
possible to combine it with QAIO 16/4 on one E-Bus
segment.
Designation QAIO 2/2-AV
Ordering number D137-001-011
Connection to MSC I/MSC II Motion Controller Via E-Bus (10 MHz)
General technical data
Connection technique Plug-in terminal strips for screwing or clamping
Mounting NS 35/7.5 mounting rail according to EN 50022 (DIN rail)
Dimensions W x D x H 124 x 170 x 85.5 mm (4.88 x 6.69 x 3.36 in)
Attachment dimensions W = 113/118.5 mm (4.45/4.66 in)
Operating temperature range +5 to +55 °C (+41 to +131 °F)
Storage temperature range -25 to +70 °C (-13 to 158 °F)
Maximum mean temperature in operation for 24 hours: +50 °C (+122 °F)
Relative air humidity 10 to 95 % (non-condensing)
Maximum operation height 2,000 m (6,500 ft)
Maxmimum storage height 3,000 m (9,800 ft)
Maximum transport height 3,000 m (9,800 ft)
Connection to M3000 modules Via E-Bus (10 MHz); please note:
- It is not possible to connect the module to an MSC D136X001-001
or D136E001-001
- Combination with QAIO 16/4 A on one E-bus segment is not possible
Dimensions, W x H x D 124 x 170 x 85.5 (attachment dimension: W = 113/118.5) mm
4.88 x 6.69 x 3.37 (attachment dimension: W = 4.45/4.67) inch
Voltage supply of module electronics 24 V DC (18-36 V DC)
The QAIO 2/2 analog module is used for local extension of
the inputs and outputs (I/O) of the Moog Servo Controller
MSC or MSC II. The analog levels are identical to the levels
of the MSC.
The module is mounted on a DIN top-hat rail and directly
connected to an MSC or MSC II via the internal extension
bus (E-bus).
Delivery:
Warranty:
All our products are covered by our own warranty.
Payment method:
Quick Quote: Receive price and availability today!
Replacing an electrical equipment unit in a plant is a complex task that requires careful planning and execution to ensure safety and minimize downtime. Here is a general step-by-step guide on how to replace electrical equipment in a plant:
Pre-Planning:
Safety Precautions:
Shutdown Procedures:
Disconnection:
Removal of Existing Equipment:
Installation of New Equipment:
Testing and Commissioning:
Documentation:
Training:
Startup:
Throughout the process, it’s important to work closely with a team that includes electrical engineers, technicians, and maintenance staff. Communication is key to a successful equipment replacement. Additionally, always adhere to local electrical codes and standards to ensure compliance and safety. If the task is beyond the expertise of in-house staff, consider hiring a professional contractor experienced in industrial electrical work.
Obtaining industrial automation programming software typically involves the following steps:
Identify Your Needs:
Research Software Options:
Contact Equipment Manufacturers:
Purchase or Download:
Academic or Evaluation Versions:
Open Source Options:
Licensing:
Training and Support:
Legal and Compliance:
Installation and Setup:
Here are some common ways to obtain industrial automation programming software:
Remember to keep your software updated to benefit from the latest features and security patches. Also, ensure that you have the necessary backup and recovery procedures in place to protect your programming work.
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.
COPYRIGHT© 2003-2024 Copyrighted
Phone(WeChat/Whatsapp)
+086-18144100983
No 1134 Jimei North Road, Jimei District
Hong Kong Office:
Guan Tang District, Hong Kong,