Honeywell Servo Valve Positioner Module (SVPM) CC-PSV201
Honeywell Servo Valve Positioner Module (SVPM) CC-PSV201
Function
This Series C I/O module provides an onboard PID positioning loop for positioning a servo valve typically used in a turbomachinery control application. It can accept LVDT/RVDT/4-20 mA position feed back signals from the control valve, receive a control valve demand remote set point from a C300-20msCEE controller and execute onboard PID positioning loop to issue current output to servo valve coil to control the control valve position.
Notable Features
• Onboard PID positioning loop execution with overall loop latency within 10 mS
• Onboard excitation supply for LVDT and support for various configurations of LVDT connections
• LVDT input channel can be optionally configured to accept 4-20 mA analog input signal
• Supports wide range of unidirectional/bidirectional current output to servo valve coil
• Servo valve output channel can optionally be configured for 4-20 mA analog output signal
• Accepts two digital inputs, which can be configured to drive servo valve output to safe value
• PID execution using the position measurement and remote set point received from the C300 20 ms controller
• Extensive module level diagnostics (PV qualification for AI & AO, LVDT excitation frequency drift check, internal reference check, power supply diagnostic, memory diagnostics, etc.)
• Extensive field level diagnostics (open wire detection for Servo, LVDT, AI [4-20 mA] and DI; LVDT core fallout; read back current diagnostics for Servo and AO [4-20 mA])
• Drive Servo output to safe value on detecting abnormal condition of control components
• Point processing at 2.5 mS period for "LVDT/RVDT signal" and PID execution
• Provides digital dither (current modulation) to compensate stiction in the controlled device (servo valve)
• Supports servo valve position calibration
• Supports redundant solution
• Supplies non-incendive field power
SVPM supports the following I/O interfaces
• LVDT/RVDT/analog input – 2 channels
• Digital input – 2 channels
• Servo/analog output – 2 channels
• 2 PID blocks
Parameter Specification
Input/Output Model CC-PSV201 - Servo Valve Positioner Module CC-TSV211 Redundant 18"
Servo Output
Output Type Bipolar current (Ranges: 10, 20, 40, 80, 160, 320 mA) Unipolar current (Ranges: 50, 300 mA) Output Channels 2 Dither 0-10% of FS, 25-60 Hz Output Temperature Drift 300 ppm per deg C Output Current Linearity 0.325% Resolution 16-bit DAC Maximum Resistive Load (24 V supply = 22 VDC through 28 VDC) Maximum coil resistances allowed for different current ranges with this interface are available in Honeywell DFS document Maximum Open Circuit Voltage ±14 V Gap (0 mA) of Output to Field on Switchover 15 mS maximum
LVDT Interface
Input/Feedback 3/4/5/6 wires LVDT feedback signals, 8 V RMS max., 2.5-3.2 KHz Excitation 8 V RMS max, 2.5-3.2 KHz (max. internal excitation is 50 mA) Frequency Stability 2.5-3.2 KHz ±5 Hz from set value Channels 2 Galvanic Isolation (any input terminal voltage referenced to common) ±500 VDC Isolation Technique Isolation transformer A/D Converter Resolution 16-bits Input/Output Range (1) 8 V RMS max., 2.5-3.2 KHz Input Impedance (voltage inputs) Impedance > 25 Kohm (2.5 KHz to 3.2 KHz) Input Scan Rate 2.5 mS Hardware Accuracy (@ CMV = 0 V) < 1% Analog Inputs * AI & LVDT signals are mutually exclusive Input Type Voltage, current (2-wire or self-powered transmitters) Input Channels 2 Common Mode Voltage, DC to 60 Hz -6 to +5 V peak A/D Converter Resolution 16-bits Input Range (1) 0 to 5 V, 1 to 5 V, 0.4 to 2 V, 4-20 mA (through 25
Maximum Normal Mode Input (differential inputs, no damage) ±30 V Input Impedance (voltage inputs) > 10 M Ω powered Maximum Input Voltage (any input referenced to common, no damage) ±30 V Input Scan Rate 5 ms Hardware Accuracy (@ CMV = 0 V) ± 0.075% of full scale (23.5°± 2°C) ± 0.15% of full scale (0 to 60°C)
Analog Outputs * AO & Servo signals are mutually exclusive
Output Type 4-20 mA Output Channels 2 Output Ripple < 100 mV across 250 Ω load Output Temperature Drift 0.005% of full scale/°C Output Readback Accuracy ±4% of full scale Output Current Linearity ±0.05% of full scale nominal Resolution ±0.05% of full scale Calibrated Accuracy ±0.35% of full scale (25o C) including linearity Directly Settable Output Current Range 0 mA, 2.9 mA to 21.1 mA Maximum Resistive Load (24 V supply = 22 VDC through 28 VDC) 760 ohms Maximum Output Compliant Voltage (24 V supply = 22 VDC through 28 VDC) 16 V Maximum Open Circuit Voltage 18 V Response Time (DAC input code to output) 1 mS Gap (0 mA) of Output to Field on Switchover 15 mS max.
Digital Inputs
Input Channels 2 DI Power Voltage Range 22 to 28 VDC ON Sense Voltage/Current 13 VDC (min.) or 6.12 mA (min.) OFF Sense Voltage/Current 5 VDC (max.) or 2.1 mA (max.) Input Impedance 4.6K Absolute Delay Across Input Filter and Isolation 1.78 mS Field Resistance for Guaranteed ON Condition 300 Ω max. @ 15 VDC Field Resistance for Guaranteed OFF Condition 30 KΩ min. @ 30 VDC
Delivery:
Warranty:
All our products are covered by our own warranty.
Payment method:
Quick Quote: Receive price and availability today!
Replacing an electrical equipment unit in a plant is a complex task that requires careful planning and execution to ensure safety and minimize downtime. Here is a general step-by-step guide on how to replace electrical equipment in a plant:
Pre-Planning:
Safety Precautions:
Shutdown Procedures:
Disconnection:
Removal of Existing Equipment:
Installation of New Equipment:
Testing and Commissioning:
Documentation:
Training:
Startup:
Throughout the process, it’s important to work closely with a team that includes electrical engineers, technicians, and maintenance staff. Communication is key to a successful equipment replacement. Additionally, always adhere to local electrical codes and standards to ensure compliance and safety. If the task is beyond the expertise of in-house staff, consider hiring a professional contractor experienced in industrial electrical work.
Obtaining industrial automation programming software typically involves the following steps:
Identify Your Needs:
Research Software Options:
Contact Equipment Manufacturers:
Purchase or Download:
Academic or Evaluation Versions:
Open Source Options:
Licensing:
Training and Support:
Legal and Compliance:
Installation and Setup:
Here are some common ways to obtain industrial automation programming software:
Remember to keep your software updated to benefit from the latest features and security patches. Also, ensure that you have the necessary backup and recovery procedures in place to protect your programming work.
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.