ovation with cavity insert 1X00458H01
ovation with cavity insert 1X00458H01
Supported HART I/O hardware: - Analog Input, 5X00058/5X00059, Version 9 or higher - Analog Input High Performance, 5X00106/5X00109, Version 6 or higher - Analog Output, 5X00062/5X00063, Version 8 or higher - Analog Output High Performance, 5X00167, Version 1 or higher • Supported FOUNDATION fieldbus I/O: - Gateway 5X00151G01 and H1 Series 2 Module 5X00152G01, Version 1 or higher - Module 5X00301 with cavity insert 1X00458H01 or Module 5X00301 with Personality Module 5X00327, Version 1 or higher (two each of 5X00301 and 5X00327 may also be configured to provide redundancy) • Supported Intrinsically Safe controller: - Ovation SIS Logic Solver, KJ2201X1-PW1, Version 1 or higher • SIS CHARM I/O - CHARMs Safety Logic Solver Version 1.1.2.15 • Supported PROFIBUS DP I/O (Ovation 3.4 and later, with the correct Ovation patch): - PROFIBUS module 5X00300/5X00321, Version 1 or higher (two each of 5X00300 and 5X00321 may also be configured to provide redundancy) • Supported Wireless Gateway (Ovation 3.4 and later) with Smart WirelessHART adapter (Ovation 3.4 and later): - 1X00693H01 through 1X00693H04
This document discusses the planning and preparation necessary for the successful
installation of an Ovation® Process Control and Information System. Ovation uses
commercially available hardware platforms, operating systems, and open network
technology.
The Ovation system consists of the following:
• Redundant high-speed network that uses Fast Ethernet standards to send input
and output data to all the stations and Controllers connected to the network.
• Workstations (Solaris-based or Windows-based) that receive and send data in
order to perform any operations needed to run a process. These workstations are
typically connected to a switch, which is, in turn, connected to the network.
• A Controller that executes modulating and sequential control strategies and
interfaces to Input and Output modules. Controllers are typically connected to
a switch, which is, in turn, connected to the network.
• Input/Output (I/O) modules that interface field signals (temperature, pressure,
and so forth) from the actual plant processes to the Controller. The Controller
sends the information over the network to the workstations. In turn, messages
are sent from the workstations to the Controller, so that adjustments can be
made, as needed, by the Controller.
5A23398G01Emerson Ovation Relay Base Contact Wetting Kit (5A23398G01)
3A99141G01Emerson Ovation Q-Line Interface (3A99141G01)
3A99162G01Emerson Ovation QBO Digital Output Card (3A99162G01)
1C31150G02Emerson Ovation Pulse Accumulator Module (1C31150G02)
1C31147G01Emerson Ovation Pulse Accumulator (1C31147G01)
5X00241G02Emerson Ovation Processor Module (5X00241G02)
5X00241G01Emerson Ovation Processor Module (5X00241G01)
5X00356G01Emerson Ovation Processor Historian Station (5X00356G01)
3A99199G01Emerson Ovation Power Supply backplane (3A99199G01)
1X00097H01Emerson Ovation Power Supply (1X00097H01)
5X00132G01Emerson Ovation Power Distribution Module (5X00132G01)
5A26137G03Emerson Ovation Power Distribution Harness (5A26137G03)
5A26137G02Emerson Ovation Power Distribution Harness (5A26137G02)
5A26137G01Emerson Ovation Power Distribution Harness (5A26137G01)
1X00102H01Emerson Ovation Power Distribution Board MagneTek WH1-PDM (1X00102H01)
1X00188H01Emerson Ovation P-mod Cavity Insert (1X00188H01)
1C31238H01Emerson Ovation P-Mod Base Cover (1C31238H01)
5A26391H03Emerson Ovation PF5133HX/512 WH3M MMX CPU Board (5A26391H03)
3A99158G02Emerson Ovation PCRL: 4PCRL2 PCI to R-Line (3A99158G02)
5A26481G01Emerson Ovation PCQL to Q-line Adapter Ribbon Cable (5A26481G01)
3A99132G02Emerson Ovation PCPS:3PCPS04 W3-DPU-PS Assembly (3A99132G02)
5A26434H01Emerson Ovation PCI PGX Graphics Card (5A26434H01)
1X00133H01Emerson Ovation PCI Fast Ethernet DAS NIC, W2K, XP (1X00133H01)
3A99200G02Emerson Ovation PCI Backplane (3A99200G02)
3A99200G01Emerson Ovation PCI Backplane (3A99200G01)
5X00105G64Emerson Ovation Kit, CPU P266, 64MB RAM, 32MB Flash, PS, FDDI/CDDI
5X00105G66Emerson Ovation Kit, CPU P266, 64MB RAM, 32MB Flash, Fast Ethernet
5X00226G02Emerson Ovation Input Output Interface Module
5X00226G01Emerson Ovation Input Output Interface Module
1B30023H02Emerson Ovation Input Output Bus Terminato
Delivery:
Warranty:
All our products are covered by our own warranty.
Payment method:
Quick Quote: Receive price and availability today!
Replacing an electrical equipment unit in a plant is a complex task that requires careful planning and execution to ensure safety and minimize downtime. Here is a general step-by-step guide on how to replace electrical equipment in a plant:
Pre-Planning:
Safety Precautions:
Shutdown Procedures:
Disconnection:
Removal of Existing Equipment:
Installation of New Equipment:
Testing and Commissioning:
Documentation:
Training:
Startup:
Throughout the process, it’s important to work closely with a team that includes electrical engineers, technicians, and maintenance staff. Communication is key to a successful equipment replacement. Additionally, always adhere to local electrical codes and standards to ensure compliance and safety. If the task is beyond the expertise of in-house staff, consider hiring a professional contractor experienced in industrial electrical work.
Obtaining industrial automation programming software typically involves the following steps:
Identify Your Needs:
Research Software Options:
Contact Equipment Manufacturers:
Purchase or Download:
Academic or Evaluation Versions:
Open Source Options:
Licensing:
Training and Support:
Legal and Compliance:
Installation and Setup:
Here are some common ways to obtain industrial automation programming software:
Remember to keep your software updated to benefit from the latest features and security patches. Also, ensure that you have the necessary backup and recovery procedures in place to protect your programming work.
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.
COPYRIGHT© 2003-2024 Copyrighted
Phone(WeChat/Whatsapp)
+086-18144100983
No 1134 Jimei North Road, Jimei District
Hong Kong Office:
Guan Tang District, Hong Kong,