ABB 216NG63A HESG441635R1 HESG216877K UNIT
ABB 216NG63A HESG441635R1 HESG216877K UNIT
The digitised measured variables derived from the primary system quantities are continuously compared by the processing unit 216VC62a with the pick-up settings of the protection functions. If a protection function picks up, the corresponding signal or tripping command is transmitted via the B448C bus to the 216AB61 O/P unit resp. to the 216DB61 I/O unit. The allocation of the signals and tripping commands at the O/P’s of the protection functions to the various channels of the 216AB61 output unit or of the 216DB61 I/P signal and tripping unit is also determined by the software installed in the 216VC62a processor unit. The output signals from the 216AB61 unit (signalling channels) and 216DB61 unit (trip channels) control the auxiliary relays K1...K16 of the 216GA61 O/P relay unit or 216GA62 tripping relay unit. The auxiliary relays' contacts are potentially-free and wired to terminals for connection to external signalling and tripping circuits. The external input signals connected to the protection energise the auxiliary relays K1...K16 in the 216GE61 I/P relay unit. The potentially-free contacts of K1...K16 transmit the external signals to the 216DB61 unit and thence to the B448C bus. By appropriate configuration of the software in the 216VC62a processing unit, external signals can be assigned to the various protection functions, e.g. for logical combination (interlocking and blocking) with trip signals or for exciting the tripping channels 1...8. Tripping circuits 1...8 can be directly energised by all or just some of the I/P channels 1...10 (K1...K10) of 216GE61 via the diode matrix (tripping logic) of 216GA62 (see Section 2.6.). Provision is also made for some of the channels 9...16 (K9...K16) of 216GE61 to be used for supervising the external tripping circuits 1...8 instead of for the connection of external inputs. This is an option, which must be specified in the order to enable the corresponding wiring to be included when engineering the protection.
Tension sensing PFCL, PFEA, PFTL series
Bailey INFI9, IMDSI02 IMMFP03 IPSYS01
Panel 800 Touch screen PP846 PP836 PP865A
AC 800PEC inverter cabinet controller
red/green LED for battery status
Woodward 5463-190
GJR5253000R0160 ABB
OVATION IC31197G01
2711-T10C15 2711-T10C15
8440-1706B
Analog output
• Allen-Bradley DF1 interface, CI534V4, 2 ch. Up to 5
• Telecontrol & SPA bus, CI535Vxx 13 Up to 5
Voltage regulator, SR511 (Tot. 2) 1
Battery charger, SB510 Up to 2
Cabinets 3, 8,11
RM500V1, IP21, IP41 or IP54: WxDxH 800x512x2125 mm,
(31.5"x20.2"x83.7")
RM500V2, IP21, IP41 or IP54: WxDxH 700x637x2225 mm,
(27.6"x25.1"x87.6")
power module
• V.24/RS232 interface, CI531, 2 ch. 5, 14 Up to 4
• MasterBus 300/300E interface
- Without slave CPU, CS513A/SC510 Up to 2
TCP/IP CI546/SC510
- With slave CPU, CS513A/SC520 6,7 Up to 6
• GCOM interface, CI543/SC510 10 Up to 5
ABB 216NG63A HESG441635R1 HESG216877K UNIT
Delivery:
Warranty:
All our products are covered by our own warranty.
Payment method:
Quick Quote: Receive price and availability today!
Replacing an electrical equipment unit in a plant is a complex task that requires careful planning and execution to ensure safety and minimize downtime. Here is a general step-by-step guide on how to replace electrical equipment in a plant:
Pre-Planning:
Safety Precautions:
Shutdown Procedures:
Disconnection:
Removal of Existing Equipment:
Installation of New Equipment:
Testing and Commissioning:
Documentation:
Training:
Startup:
Throughout the process, it’s important to work closely with a team that includes electrical engineers, technicians, and maintenance staff. Communication is key to a successful equipment replacement. Additionally, always adhere to local electrical codes and standards to ensure compliance and safety. If the task is beyond the expertise of in-house staff, consider hiring a professional contractor experienced in industrial electrical work.
Obtaining industrial automation programming software typically involves the following steps:
Identify Your Needs:
Research Software Options:
Contact Equipment Manufacturers:
Purchase or Download:
Academic or Evaluation Versions:
Open Source Options:
Licensing:
Training and Support:
Legal and Compliance:
Installation and Setup:
Here are some common ways to obtain industrial automation programming software:
Remember to keep your software updated to benefit from the latest features and security patches. Also, ensure that you have the necessary backup and recovery procedures in place to protect your programming work.
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.
COPYRIGHT© 2003-2024 Copyrighted
Phone(WeChat/Whatsapp)
+086-18144100983
No 1134 Jimei North Road, Jimei District
Hong Kong Office:
Guan Tang District, Hong Kong,