triconex 3382 Pulse Input Module, Enhanced
triconex 3382 Pulse Input Module, Enhanced
![]()
Feature Specification
Points 32, commoned
Nominal input current 4–20 mA DC
Operational current range 2–22 mA DC
Absolute maximum field voltage 33 V DC
Absolute maximum reverse field voltage – 0.6 V DC
Absolute maximum input current 50 mA DC
Input bandwidth (3dB) 16 Hz
Source impedance 180 Ω
Input impedance (with baseplate) 250 Ω
I to V resistor 100 Ω, ±0.01%
Resolution 12 bits
Absolute error 0.15% of full scale (20 mA)
Diagnostic Force-to-value diagnostic (FVD)
Scan time <1 ms for all 32 points
Functional-to-protective-earth isolation 500 V DC, minimum
Functional-to-functional-earth (logic)
isolation
800 V DC, minimum
The Tricon is a state-of-the art
controller that provides fault tolerance
by means of Triple-Modular Redundant
(TMR) architecture. TMR integrates
three isolated, parallel control systems
and extensive diagnostics in one control
system. The system uses two-out-ofthree
voting to provide high-integrity,
error-free, uninterrupted process operation
with no single point of failure.
The Tricon controller uses three identical
channels. Each channel independently
executes the control program in
parallel with the other two channels.
Specialized hardware/software voting
mechanisms qualify and verify all
digital inputs and outputs from the
field, while analog inputs are subject to
a mid-value selection process.
Because each channel is isolated from
the others, no single-point failure in any
channel can pass to another. If a hardware
failure does occur on one channel,
the other channels override it. Meanwhile
the faulting module can easily be
removed and replaced while the
controller is online without interrupting
the process.
Setting up control programs is simplified
with the triplicated Tricon system,
because it operates as a single control
system from the user’s point of view.
The user terminates sensors and actuators
at a single wiring terminal and
programs the Tricon with one set of
control program logic. The Tricon
controller manages the rest!
----------------------------------
| TRICONEX 9300 PLC Module Via |
| EPRO PR6426/000-000+CON021/916-120 PLC Module Via |
| YOKOGAWA YCB147-5/BR PLC Module Via |
| Honeywell CC-PDIL01 51405040-176 Digital Input Module 1x Sealed Via |
| YOKOGAWA YCB147-F PLC Module Via |
| BMXEHC0800 brand new original programmable controller PLC module, free shipping |
| YOKOGAWA ANB10D-415/CU2N/NDEL BASE PLATE PLC Module Via |
| YOKOGAWA AIP504-11 S1 PLC Module Via |
| YOKOGAWA NFDV551-P10 S2 PLC Module Via |
| YOKOGAWA NFSB100-S50/SBT01 PLC Module Via |
| DS200UCIAG1A GE Mark V Speedtronic Motherboard Module Via |
| GE 029.359 329 PLC Module Via |
| BACHMANN MPC240-128/512 CF 00012711-44 PLC Module Via |
| YOKOGAWA F3DA08-5R PLC Module Via |
| BACHMANN MPC240W 64 PLC Module Via |
| YOKOGAWA NFAR181-S50/R8S10 RTD Input Module Via |
| YOKOGAWA ASI533-S00/SS3S0 PLC Module Via |
| YOKOGAWA SAI143-H53 S3 PLC Module Via |
| EMERSON EPRO A6312/08 Speed and Key Module 1XNew Ship By UPS |
| BACHMANN RS204/T PLC Module Via |
| BENTLY NEVADA 3500/62 136483-01 Isolated I/O Module 1x New Via |
| 3708E TRICONEX Module PLC Via |
| BENTLY NEVADA 149776-02 Via |
| TRICONEX 4119A and original |
| OVATION WESTINGHOUSE Inverter 220VDC/230VAC 500V (ADVEL) PLC Module Via/DH |
| YOKOGAWA ANB10D-425-CU2T S2 PLC Module Via |
| 3500/05-02-04-01-00-00 Bently Nevada PLC Chassis System Rack Via |
| YOKOGAWA EB511-10 PLC Module Via |
| Honeywell 51403393-100 PLC Module Via |
| EMERSON 396509-03-7 1x New Via |
| IC697CMM742 GE-Fanuc Industrial Control System Via |
| Honeywell 10205/2/1 PLC Module Via |
| GE 895136 PLC Module Via |
| YOKOGAWA FU20-05-T1-NPT PH/ORP Combination Sensor Module Via |
| YOKOGAWA SRM53D-000/BR4 PLC Module Via |
| YOKOGAWA SAI143-H53/PRP PLC Module Via |
| AB PLC-5 1785-LT3 Processor Module 1x New Via |
| YOKOGAWA PW302 S4 Power Supply Module Via |




Delivery:
Warranty:
All our products are covered by our own warranty.
Payment method:
Quick Quote: Receive price and availability today!
Replacing an electrical equipment unit in a plant is a complex task that requires careful planning and execution to ensure safety and minimize downtime. Here is a general step-by-step guide on how to replace electrical equipment in a plant:
Pre-Planning:
Safety Precautions:
Shutdown Procedures:
Disconnection:
Removal of Existing Equipment:
Installation of New Equipment:
Testing and Commissioning:
Documentation:
Training:
Startup:
Throughout the process, it’s important to work closely with a team that includes electrical engineers, technicians, and maintenance staff. Communication is key to a successful equipment replacement. Additionally, always adhere to local electrical codes and standards to ensure compliance and safety. If the task is beyond the expertise of in-house staff, consider hiring a professional contractor experienced in industrial electrical work.
Obtaining industrial automation programming software typically involves the following steps:
Identify Your Needs:
Research Software Options:
Contact Equipment Manufacturers:
Purchase or Download:
Academic or Evaluation Versions:
Open Source Options:
Licensing:
Training and Support:
Legal and Compliance:
Installation and Setup:
Here are some common ways to obtain industrial automation programming software:
Remember to keep your software updated to benefit from the latest features and security patches. Also, ensure that you have the necessary backup and recovery procedures in place to protect your programming work.
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.
COPYRIGHT© 2003-2025 Copyrighted
Phone(WeChat/Whatsapp)
+086-181 4410 0983
No 1134 Jimei North Road,
Hong Kong Office:
Guan Tang District, Hong Kong,