Triconex 2480A-F
Analog Output Baseplate Kit,
Hazardous Location
Triconex 2480A-F Analog Output Baseplate Kit, Hazardous Location
Controller Features
The Trident controller is a state-of-the-art programmable logic and process controller that
provides a high level of system fault tolerance. To help ensure the highest possible system
integrity at all times, the Trident controller includes these features:
• Provides Triple Modular Redundant (TMR) architecture whereby each of three
identical system channels independently executes the control program, and specialized
hardware/software mechanisms “vote” all inputs and outputs.
• Withstands harsh industrial environments.
• Enables field installation and repair to be done at the module level while the controller
remains online. Replacing an I/O module does not disturb field wiring.
• Supports I/O modules (analog and digital) and an optional Communication Module
that interfaces with Modbus masters and slaves, other Triconex controllers in Peer-to-
Peer networks, and external host applications on Ethernet networks.
• Support for:
— 25 I/O baseplates maximum
— 416 AI points maximum (13 AI baseplates, 13 AI/DI baseplates, or any combination
that does not exceed 416 total AI or AI/DI points)
— 20 AO points maximum (5 baseplates)
— 640 DI points maximum (20 DI baseplates, 13 AI/DI baseplates, or any combination
that does not exceed 640 total DI points)
— 320 DO points maximum (20 baseplates)
— 30 PI points maximum (5 baseplates)
— 640 SRO points maximum (20 baseplates)
• Integrates the I/O module with the termination assembly.
• Executes control programs developed and debugged with TriStation™ 1131 software.
• Allows normal maintenance while the Trident controller is operating, without
disturbing the controlled process.
• Provides TriStation 1131 and Modbus communication from the Communications
Integration Module (CIM), Communication Module (CM), or Main Processor (MP).
• Provides a dedicated co-processor that controls the input and output modules to
reduce the workload of the MP. Each I/O module is supported by custom applicationspecific
integrated circuits (ASICs), which scan inputs and perform diagnostics to
detect hardware faults. Output module ASICs do the following:
— Supply information for voting of output data.
— Check I/O loop-back data from the output terminal for final validation of the
output state.
— Perform diagnostics to detect hardware and field-wiring problems.
• Provides integral online diagnostics with adaptive-repair capabilities.
• Supports hot-spare I/O modules for critical applications where prompt service may not
be possible.
• Provides integral support for redundant field and logic power sources.
System Configuration
Physically, a basic Trident controller consists of MPs, I/O modules, an optional CM (v2 or v3
systems) or CIM (v3 systems), the baseplates on which the modules are mounted, field wiring
connections, and a PC running the TriStation 1131 software. This section briefly describes these
components.
A typical Trident system is configured into one or more vertical I/O columns guided by DIN
rails and mounted on a sheet-metal panel. Trident modules are field-replaceable units
consisting of an electronic assembly housed in a metal spine. Each module has a protective
cover that helps ensure no components or circuits are exposed even when a module is removed
from the rail. Offset backplane connectors make it impossible to plug a module in upside down,
and keys on each module help prevent the insertion of modules into incorrect slots. The Trident
controller supports digital and analog input and output points, as well as pulse and
thermocouple inputs and multiple communication protocols.
Controller Configuration
A basic Trident system consists of one MP assembly, an optional CIM or CM assembly, and I/O
assemblies. Assemblies are configured into a system on a mounting plate using interconnect
assemblies, extenders, I/O bus cables, and I/O bus terminators. I/O modules communicate
with the MPs by means of a triplicated, RS-485, bi-directional communication bus, called the
I/O bus.
----------------------------------
| Brand New TRICONEX 3625A Triconex Module Tricon 3625A |
| Honeywell TK-FFSU01 51309582-275 PLC Module 1x New Via |
| FUJI NC1B10 PLC Backplate Via |
| Honeywell CC-PAIN01 51410069-175 Analog Input Module 1x New Sealed Via |
| TRICONEX 4351B Brand and original |
| NEW Schneider ATV610D90N4 frequency converter Original and authent 90KW |
| 1C31234G01 Westinghouse OVATION Emerson Contact Input Process Control PLC -FEDEX |
| KJ3101X1-BB1 EMERSON DeltaV FISHER-ROSEMOUNT DI Discrete Via |
| EMERSON EP-7641 EP-7641-C Power Motion Module Via |
| BENTLY NEVADA 3300/50-01-01-00-01 TACHOMETER MONITOR Module 1x New Via |
| EPRO CON021/916-200+PR6426/000-130 PLC Module Via |
| 3504E | Triconex Invensys Digital Input Module Via |
| 3500/05-02-04-00-00-01 | Bently Nevada PLC Chassis System Rack Via |
| Honeywell CC-TDOB01 51308371-175 Baseplate Board 1x NEW Via |
| Moxa ICF-1150I-S-SC-T Serial to Fiber Converter Via |
| Honeywell 2MLF-AD8A PROGRAMMABLE LOGIC CONTROLLER Via |
| 1x brand New ThermoFisher 101427-00 electrical machinery |
| Honeywell MC-TAMT04 51305890-175 Low Level Input Multiplexer Via |
| Honeywell 51303948-100 48V HONEYWELL HPM BATTERY ASSEMBLY Via |
| TRICONEX 3805E Analog Output Module Card 3805E Factory Sealed TRICONEX 3805E |
| FOXBORO ROSENBERGER P0972KW FIBER OPTIC CABLE 15m Via |
| EVS9330-ES LENZE (by DHL or ) #U596C YG/# - DHL/Fedex |
| Schneider MN-S3 MicroNet Sensor with Setpoint Adjustment Via |
| 51202329-732 | Honeywell Violet Extension Cable Via |
| YOKOGAWA UT55A-040-11-00/LP Controller Module Via |




Delivery:
Warranty:
All our products are covered by our own warranty.
Payment method:
Quick Quote: Receive price and availability today!
Replacing an electrical equipment unit in a plant is a complex task that requires careful planning and execution to ensure safety and minimize downtime. Here is a general step-by-step guide on how to replace electrical equipment in a plant:
Pre-Planning:
Safety Precautions:
Shutdown Procedures:
Disconnection:
Removal of Existing Equipment:
Installation of New Equipment:
Testing and Commissioning:
Documentation:
Training:
Startup:
Throughout the process, it’s important to work closely with a team that includes electrical engineers, technicians, and maintenance staff. Communication is key to a successful equipment replacement. Additionally, always adhere to local electrical codes and standards to ensure compliance and safety. If the task is beyond the expertise of in-house staff, consider hiring a professional contractor experienced in industrial electrical work.
Obtaining industrial automation programming software typically involves the following steps:
Identify Your Needs:
Research Software Options:
Contact Equipment Manufacturers:
Purchase or Download:
Academic or Evaluation Versions:
Open Source Options:
Licensing:
Training and Support:
Legal and Compliance:
Installation and Setup:
Here are some common ways to obtain industrial automation programming software:
Remember to keep your software updated to benefit from the latest features and security patches. Also, ensure that you have the necessary backup and recovery procedures in place to protect your programming work.
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.
COPYRIGHT© 2003-2025 Copyrighted
Phone(WeChat/Whatsapp)
+086-181 4410 0983
No 1134 Jimei North Road,
Hong Kong Office:
Guan Tang District, Hong Kong,