Triconex 2402-F
Digital Output Baseplate Kit,
High Voltage
Triconex 2402-F Digital Output Baseplate Kit, High Voltage 2402A-F
Controller Features
The Trident controller is a state-of-the-art programmable logic and process controller that
provides a high level of system fault tolerance. To help ensure the highest possible system
integrity at all times, the Trident controller includes these features:
• Provides Triple Modular Redundant (TMR) architecture whereby each of three
identical system channels independently executes the control program, and specialized
hardware/software mechanisms “vote” all inputs and outputs.
• Withstands harsh industrial environments.
• Enables field installation and repair to be done at the module level while the controller
remains online. Replacing an I/O module does not disturb field wiring.
• Supports I/O modules (analog and digital) and an optional Communication Module
that interfaces with Modbus masters and slaves, other Triconex controllers in Peer-to-
Peer networks, and external host applications on Ethernet networks.
• Support for:
— 25 I/O baseplates maximum
— 416 AI points maximum (13 AI baseplates, 13 AI/DI baseplates, or any combination
that does not exceed 416 total AI or AI/DI points)
— 20 AO points maximum (5 baseplates)
— 640 DI points maximum (20 DI baseplates, 13 AI/DI baseplates, or any combination
that does not exceed 640 total DI points)
— 320 DO points maximum (20 baseplates)
— 30 PI points maximum (5 baseplates)
— 640 SRO points maximum (20 baseplates)
• Integrates the I/O module with the termination assembly.
• Executes control programs developed and debugged with TriStation™ 1131 software.
• Allows normal maintenance while the Trident controller is operating, without
disturbing the controlled process.
• Provides TriStation 1131 and Modbus communication from the Communications
Integration Module (CIM), Communication Module (CM), or Main Processor (MP).
• Provides a dedicated co-processor that controls the input and output modules to
reduce the workload of the MP. Each I/O module is supported by custom applicationspecific
integrated circuits (ASICs), which scan inputs and perform diagnostics to
detect hardware faults. Output module ASICs do the following:
— Supply information for voting of output data.
— Check I/O loop-back data from the output terminal for final validation of the
output state.
— Perform diagnostics to detect hardware and field-wiring problems.
• Provides integral online diagnostics with adaptive-repair capabilities.
• Supports hot-spare I/O modules for critical applications where prompt service may not
be possible.
• Provides integral support for redundant field and logic power sources.
System Configuration
Physically, a basic Trident controller consists of MPs, I/O modules, an optional CM (v2 or v3
systems) or CIM (v3 systems), the baseplates on which the modules are mounted, field wiring
connections, and a PC running the TriStation 1131 software. This section briefly describes these
components.
A typical Trident system is configured into one or more vertical I/O columns guided by DIN
rails and mounted on a sheet-metal panel. Trident modules are field-replaceable units
consisting of an electronic assembly housed in a metal spine. Each module has a protective
cover that helps ensure no components or circuits are exposed even when a module is removed
from the rail. Offset backplane connectors make it impossible to plug a module in upside down,
and keys on each module help prevent the insertion of modules into incorrect slots. The Trident
controller supports digital and analog input and output points, as well as pulse and
thermocouple inputs and multiple communication protocols.
Controller Configuration
A basic Trident system consists of one MP assembly, an optional CIM or CM assembly, and I/O
assemblies. Assemblies are configured into a system on a mounting plate using interconnect
assemblies, extenders, I/O bus cables, and I/O bus terminators. I/O modules communicate
with the MPs by means of a triplicated, RS-485, bi-directional communication bus, called the
I/O bus.
----------------------------------
| YOKOGAWA F3PU20-0S Power Supply Module Via |
| YOKOGAWA SSB401-53 S9343FA Connector/Terminal Module Via |
| EMERSON DELTAV KJ3221X1-BA2 AO SERIES 2 Module Via |
| YOKOGAWA EC401-11 S2 Bus Coupler Module Via |
| MA2211-100 TRICONEX Control Module Cards Via |
| Honeywell 8C-PDIDA1 PLC Digital Output Module Via |
| TRICONEX 4508 High Speed Channel Interface Module |
| NEW PLCTSX312422 by DHL or EMS |
| YOKOGAWA NFCB301-C100 PLC Module Via |
| T9451 ICS Triplex Rockwell Digital Output Module 24VDC 8CH 1x New Via |
| YOKOGAWA F3YP12-0V S1 Position Module Via |
| ABB EL3020 Continuous Gas Analyzer 3.259700.5 Via |
| TRICONEX 3721N Module |
| YOKOGAWA KS9-05*B PLC Cable Via |
| YOKOGAWA SB401-11 Terminal Block PLC Module Via |
| 馃叞锔忦煍?TRICONEX 3706 (DHL or 90days Warranty) |
| EPRO CON021/916-240 PLC Module Via |
| BACHMANN WT305E PLC Module Via |
| TRICONEX 3636R OUTPUT MODULE 3636R 3636R |
| EMERSON WESTINGHOUSE PROCESS CONTROL 3A99200G01 VIA |
| Veichi AC70-T3-011G/015P Frequency Converter 1x New Via DHL/FedEX |
| NEW Triconex 3625C1 3625C1 |
| YOKOGAWA AIP512 S2 PLC Module Via |
| BACHMANN MPC270-128/512MB PLC Module Via |
| TRICONEX 3636R TRICONEX 3636R MODULE TRICONEX 3636R TRICONEX 3636R Module Card |
| ABB Bailey IMFCS01 Symphony Frequency Counter Module Infi-90 Via |
| YOKOGAWA PW401 S4 Power Supply Module Via |
| 1C31205G01 OVATION WESTINGHOUSE EMERSON Remote Node Base Assembly Via |
| BENTLY NEVADA 3500/90 125728-01 Communication Gateway Module Via |
| TRICONEX 3351 Power Supply Module Unit Via |
| YOKOGAWA F3BU09-0N/D2 Baseboard Via |
| P0926JF New FOXBORO INVENSYS Backplane Via |
| YOKOGAWA UT35A-001-11-00/LP/DC Temperature Controller Panel Module Via |
| YOKOGAWA SB401-50 S1 Bus Interface Module Via |
| TRICONEX 4201 and original |
| 1x Brand New TAMAGAWA encoder TS2651N111E78 |
| TRICONEX 3664 Via |
| BENTLY NEVADA 3300/50-02-01-00-01 TACHOMETER MONITOR Module 1x New Via |
| TRICONEX 3805E Analog Output Module Card 3805E TRICONEX 3805E |
| Honeywell RS232 CABLE 5M Via |
| Honeywell SC-UMIX01 51307550-175 IOTA 28 Bottom Terminals Module Via |
| TRICONEX 4200 Digital Output Module Via |
| Honeywell MC-GAIH13 51304718-175 Analog Input FTA Redundancy Via |
| ES2403 NIDEC/ EMERSON frequency converter ES2403 11KW CT Inverter - DHL/Fedex |
| 5X00499G01 Ovation Module Digital Input 24VDC Singl 32CH 1x New |
| Honeywell Sieger Zellweger 05701-A-0511 Rack Via |
| BENTLY NEVADA 3300/50-02-02-00-00 TACHOMETER MONITOR Module 1x New Via |
| TRICONEX CM3201 Module CM3201 Brand New with box Via |
| NEW Triconex 4119A by DHL or |
| CEV58M-00299 Encoder CEV58M-00299 Brand New |
| Triconex 3721 New 3721 Analog Input Module DHL |
| EPI3382 Triconex 3382 New EPI3382 Triconex 3382 Module DHL |
| YOKOGAWA AMM12 S3 Circuit Board Via |
| HONEYWELL FSC FC-TSDI-1624 24VDC Via |
| 1C31203G01 | WESTINGHOUSE OVATION Emerson Remote Node Controller Module - |
| 5X00226G03 Ovation I/O Interface Module New 1x Via DHL/FEDEX/UPS |
| YOKOGAWA UT-150L TEMPERATURE CONTROLLER Module Via |
| 4352AN Triconex Tricon Communication Module TCM Via |
| YOKOGAWA KS1-10 PLC Cable Via |




Delivery:
Warranty:
All our products are covered by our own warranty.
Payment method:
Quick Quote: Receive price and availability today!
Replacing an electrical equipment unit in a plant is a complex task that requires careful planning and execution to ensure safety and minimize downtime. Here is a general step-by-step guide on how to replace electrical equipment in a plant:
Pre-Planning:
Safety Precautions:
Shutdown Procedures:
Disconnection:
Removal of Existing Equipment:
Installation of New Equipment:
Testing and Commissioning:
Documentation:
Training:
Startup:
Throughout the process, it’s important to work closely with a team that includes electrical engineers, technicians, and maintenance staff. Communication is key to a successful equipment replacement. Additionally, always adhere to local electrical codes and standards to ensure compliance and safety. If the task is beyond the expertise of in-house staff, consider hiring a professional contractor experienced in industrial electrical work.
Obtaining industrial automation programming software typically involves the following steps:
Identify Your Needs:
Research Software Options:
Contact Equipment Manufacturers:
Purchase or Download:
Academic or Evaluation Versions:
Open Source Options:
Licensing:
Training and Support:
Legal and Compliance:
Installation and Setup:
Here are some common ways to obtain industrial automation programming software:
Remember to keep your software updated to benefit from the latest features and security patches. Also, ensure that you have the necessary backup and recovery procedures in place to protect your programming work.
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.
COPYRIGHT© 2003-2025 Copyrighted
Phone(WeChat/Whatsapp)
+086-181 4410 0983
No 1134 Jimei North Road,
Hong Kong Office:
Guan Tang District, Hong Kong,