Bently 3500/61 163179-02 Temperature Modules
The 3500/60 & 61 modules provide six channels of temperature monitoring and accept both Resistance Temperature Detector (RTD) and Thermocouple (TC) temperature inputs. The modules condition these inputs and compare them against user-programmable alarm setpoints.
The 3500/60 and 3500/61 provide identical functionality except that the 3500/61 provides recorder outputs for each of its six channels while the 3500/60 does not. The user programs the modules to perform either RTD or TC temperature measurements using the 3500 Rack Configuration Software. Different I/O modules are available in RTD/TC non-isolated or TC isolated versions. The user can configure the RTD/TC non-isolated version to accept either TC or RTD, or a mixture of TC and RTD inputs. The TC isolated version provides 250 Vdc of channel-to-channel isolation to protect against external interference.
When used in a Triple Modular Redundant (TMR) configuration, temperature monitors must be installed adjacent to each other in groups of three. When used in this configuration, the system employs two types of voting to ensure accurate operation and to avoid single-point failures
3500/60 Nominal consumption of 7 watts.
3500/61 Nominal consumption of 9 watts.
Front Panel LEDs
OK LED Indicates when the Temperature Monitor is operating properly.
TX/RX LED Indicates then the Temperature Monitor is communicating with other modules in the 3500 rack.
Bypass LED Indicates when the Temperature Monitor is in Bypass Mode.
-------------------------------
3500/60-02-00
3500/60-03-00
3500/60-04-00
3500/60-05-00
3500/60-01-01
3500/60-02-01
3500/60-03-01
3500/60-04-01
3500/60-05-01
3500/61-01
3500/61-02
3500/61-03
3500/61-04
3500/61-05
3500/61-01-00
3500/61-02-00
3500/61-03-00
3500/61-04-00
3500/61-05-00
3500/61-01-01
3500/61-02-01
3500/61-03-01
3500/61-04-01
3500/61-05-01
133908-01
133916-01
133924-01
133932-01
133892-01
134544-0005-01
134544-0007-01
134544-0010-01
134544-0025-01
134544-0050-01
134544-0100-01
134544-0005-02
134544-0007-02
134544-0010-02
134544-0025-02
134544-0050-02
134544-0100-02
133908-01
133916-01
133924-01
133932-01
00580442
00580443
00502133
00580444
04425545
04400037
134542-01
133811-01
135344-01
133819-01
133827-01
133835-01
133843-01
136711-01
133811-02
135343-01
133819-02
133827-02
133835-02
133843-02
133892-01
133900-01
136711-02
3500/62-01
3500/62-02
3500/62-03
3500/62-04
3500/62-05
3500/62-01-00
3500/62-02-00
3500/62-03-00
3500/62-04-00
3500/62-05-00
3500/62-01-01
3500/62-02-01
3500/62-03-01
3500/62-04-01
3500/62-05-01
136595-01
136603-01
133811-03
136590-01
04425545
04400037
136491-01
136499-01
136294-01
136483-01
137110-01
136973-01
01700059
3500/72M-01
3500/72M-02
3500/72M-03
3500/72M-01-00
3500/72M-02-00
3500/72M-03-00
3500/72M-01-01
3500/72M-02-01
3500/72M-03-01
125808-08
128015-08
128702-01
128710-01
149734-08
140471-01
140482-01
135489-01
146479-01
00580434
00580441
00502133
3500/77M-03
3500/77M-04
3500/77M-03-00
3500/77M-04-01
146282-01
140734-07
143729-01
143737-01
00580434
00580441
146973-01
145732-01
146622-01
146877-01
146877-02
146877-03
146877-04
146877-05
146877-06
146877-11
146877-12
146877-13
146877-14
146877-15
146877-16
146877-17
146879-01
146824-0010
146824-0025
146824-0050
146824-0100
146824-0200
146824-0300
146824-0400
146824-0500
146824-1000
3500/92-01
3500/92-02
3500/92-03
Delivery:
Warranty:
All our products are covered by our own warranty.
Payment method:
Quick Quote: Receive price and availability today!
Replacing an electrical equipment unit in a plant is a complex task that requires careful planning and execution to ensure safety and minimize downtime. Here is a general step-by-step guide on how to replace electrical equipment in a plant:
Pre-Planning:
Safety Precautions:
Shutdown Procedures:
Disconnection:
Removal of Existing Equipment:
Installation of New Equipment:
Testing and Commissioning:
Documentation:
Training:
Startup:
Throughout the process, it’s important to work closely with a team that includes electrical engineers, technicians, and maintenance staff. Communication is key to a successful equipment replacement. Additionally, always adhere to local electrical codes and standards to ensure compliance and safety. If the task is beyond the expertise of in-house staff, consider hiring a professional contractor experienced in industrial electrical work.
Obtaining industrial automation programming software typically involves the following steps:
Identify Your Needs:
Research Software Options:
Contact Equipment Manufacturers:
Purchase or Download:
Academic or Evaluation Versions:
Open Source Options:
Licensing:
Training and Support:
Legal and Compliance:
Installation and Setup:
Here are some common ways to obtain industrial automation programming software:
Remember to keep your software updated to benefit from the latest features and security patches. Also, ensure that you have the necessary backup and recovery procedures in place to protect your programming work.
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.
COPYRIGHT© 2003-2024 Copyrighted
Phone(WeChat/Whatsapp)
+086-18144100983
No 1134 Jimei North Road, Jimei District
Hong Kong Office:
Guan Tang District, Hong Kong,