HIMA Processor module
Analog input module X-AI 32 51 32 channels, 04 ... 20 mA
2500-C100 - CPU w/128K user memory
Digital input module X-DI 16 01 16 channels, 120 VAC, SIL 3
Analog input module X-AI 16 51 16 channels, 04 … 20 mA, ±280 mV, galvanically isolated, thermocouple TC, Pt100
Analog input module X-AI 32 01 32 channels, 4 ... 20 mA, line monitoring, SIL 3
Analog input module X-AI 32 02 32 channels, 4 ... 20 mA, line monitoring, SOE, SIL 3
Analog input module X-AI 32 51 32 channels, 04 ... 20 mA, line monitoring
Counter module X-CI 24 01 24 channels, 0 ... 20 kHz, SIL 3
Counter module X-CI 24 51 24 channels, 0 ... 20 kHz
Output modules
Digital output module X-DO 32 01 32 channels, 24 VDC, 0,5 A, short-circuit monitoring LS, individual channel shut-off, SIL 3
Digital output module X-DO 32 51 32 channels, 24 VDC, 0,5 A, protected outputs, group shut-off
Digital output module X-DO 24 01 24 channels, 24 VDC, 0,5 A, line monitoring LSLB, individual channel shut-off, SIL 3
Digital output module X-DO 24 02 24 channels, 48 VDC, 0,5 A, line monitoring LSLB, individual channel shut-off, SIL 3
Relay output module X-DO 12 01 12 channels, 230 VACDC, current measurement, cycle counting, SIL 3
Digital output module X-DO 12 02 12 channels, 24 VDC, 2 A, short-circuit monitoring LS, individual channel shut-off, SIL 3
Relay output module X-DO 12 51 12 channels, 230 VACDC
Analog output module X-AO 16 01 16 channels, 4 ... 20 mA, pairwise galvanically isolated
Analog output module X-AO 16 51 16 channels, 4 ... 20 mA
Further modules
HART communication module X-HART 32 01 32 modems, SIL 3, X-AI 32 01, X-AI 32 02, X-AI 32 51, X-AO 16 01, X-AO 16 51
Delivery:
Warranty:
All our products are covered by our own warranty.
Payment method:
Quick Quote: Receive price and availability today!
Replacing an electrical equipment unit in a plant is a complex task that requires careful planning and execution to ensure safety and minimize downtime. Here is a general step-by-step guide on how to replace electrical equipment in a plant:
Pre-Planning:
Safety Precautions:
Shutdown Procedures:
Disconnection:
Removal of Existing Equipment:
Installation of New Equipment:
Testing and Commissioning:
Documentation:
Training:
Startup:
Throughout the process, it’s important to work closely with a team that includes electrical engineers, technicians, and maintenance staff. Communication is key to a successful equipment replacement. Additionally, always adhere to local electrical codes and standards to ensure compliance and safety. If the task is beyond the expertise of in-house staff, consider hiring a professional contractor experienced in industrial electrical work.
Obtaining industrial automation programming software typically involves the following steps:
Identify Your Needs:
Research Software Options:
Contact Equipment Manufacturers:
Purchase or Download:
Academic or Evaluation Versions:
Open Source Options:
Licensing:
Training and Support:
Legal and Compliance:
Installation and Setup:
Here are some common ways to obtain industrial automation programming software:
Remember to keep your software updated to benefit from the latest features and security patches. Also, ensure that you have the necessary backup and recovery procedures in place to protect your programming work.
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.
COPYRIGHT© 2003-2024 Copyrighted
Phone(WeChat/Whatsapp)
+086-18144100983
No 1134 Jimei North Road, Jimei District
Hong Kong Office:
Guan Tang District, Hong Kong,