GE Vernova’s Mark VIe control system UCSE

GE Vernova’s Mark VIe control system is an integrated control
system that is widely used in a diverse range of applications
including gas and steam turbines, safety systems, wind
turbines, gasification, hydro, nuclear, and combined cycle
power plants. These diverse applications require a controller
that can deliver the high performance and flexibility needed
to run application specific control reliably.
The Mark VIe UCSE is a stand-alone controller that uses
QNX® Neutrino, a real-time, multi-tasking operating system
(OS), to run application-specific control system logic.
The UCSE controller offers the following advantages:
• Single module
• No battery
• No jumper settings required
• ToolboxST programmatically updates the host application
board programmable devices
The UCSE controller mounts in a panel and communicates with
I/O modules through on-board I/O network (IONet), PROFINET,
High-speed Serial Link (HSSL), and/or other interfaces.
The available versions of the UCSE controller are: UCSEH2A
for Mark VIe, UCSEH2B for Mark VIe, LS2100e Static Starters,
and EX2100e Voltage Regulators, and UCSEH2C for EX2100e
Static Exciters.
Input Power
• UCSEH2A : 42-61 Watts
• UCSEH2B : 23-37 Watts
• UCSEH2C: 27-41 Watts
Input Voltage
• 18- 50 VDC
Operating Temperature
• UCSEH2A: -40 to 65°C with 0.5 m/s vertical airflow
• UCSEH2A: -40 to 52°C with convection cooling
• UCSEH2B: -40 to 58°C with convection cooling
• UCSEH2C: -40 to 60°C with convection cooling
Storage Temperature
• -45°C to 85°C
Humidity
• 5% to 95% non-condensing
Microprocessor
• UCSEH2A: quad core, 2.8 GHz 11th Gen Intel®
CoreTM i7
• UCSEH2B: dual core, 1.2 GHz 11th Gen Intel®
CoreTM i7
• UCSEH2C: quad core, 1.2 GHz 11th Gen Intel®
CoreTM i7
Memory
• 8 GB DDR4-2400
Non Volatile Memory
• 6139 non-volatile program variables, 338 forces,
and 128 totalizers
Storage
• 80 GB NVME SSD (18GB allocated)
Required Software
• ControlST V07.10.02C or later
Ports
UCSEH2A, UCSEH2B:
• 8 Ethernet ports on front panel
• 1 USB-C port (labeled USB) only used to initially
set up UDH network IP address or for restore
function
• 1 USB-C port (labeled COM) is
115200 bit/s, 8N1, no Flow-Control, serial redirection
UCSEH2C:
• 12 Ethernet ports on front panel
• 1 USB-C port (labeled USB) only used to initially set
up UDH network IP address or for restore function
• 1 USB-C port (labeled COM) is 115200 bit/s, 8N1,
no Flow-Control, serial redirection
Dimensions
• UCSEH2A, UCSEH2C: 166.36 x 168.28 x 85.00 mm
• UCSEH2A, UCSEH2C with mounting: 203.48 x
171.45 x 85.00 mm
• UCSEH2B: 166.35 x 168.28 x 56.00 mm
• UCSEH2B with mounting: 203.48 x 169.88 x
56.00 mm
Interoperability
• Can communicate with all previous generation
Mark Vie Controllers
• Interoperable within a redundancy set with
UCSBH1A, UCSBH4A, UCSCH2A refer to
GEI-100871
Mounting
• Direct mount to base using two to four
mounting screws.
• Vertical mount with unobstructed air flow
through fins.
• 100 mm minimal air gap above the UCSE.
• Parallel mounting requirements differ between
models and redundancy – refer to GEH-6721
Vol II
• Ambinet temperature envelope is 25 mm from
any point in UCSE.
Miscellaneous
• 121T8700P0002 UCSB to UCSC/UCSE Power
Cable Adapter
• 127T2669P0001 UCSB/CSLA to UCEC/UCSE
Module Power Cable Adapter
EU
• CE Mark
• EMC Directive
– EN 61000-6-2:2019
– IEC/EN 61000-6-4:2019 (reference CISPR 32)
– CISPR 11:2015 / EN 55011:2016+A11:2020
– IEC 61000-4-18:2019 / EN 61000-4-18:2019
– IEC 61326-3-1:2017
– 2011/65/EU + 2015/863
• ATEX Directive
– Category 3 equipment - II 3 G
– EN IEC 60079-0:2018
– EN IEC 60079-7:2015/A1:2018]
• RoHS Directive
• REACH Regulation
• WEEE Directive
US
• FCC 47 CFR 15 Subpart B, Class A
• Hazardous Locations
– UL 61010-1 Ed. 3, CSA C22.2 No. 61010-1 Ed. 3
– UL 61010-2-201 Ed. 2, CSA C22.2 No.
61010-2-201 Ed. 2
– UL 121201 Ed. 9, CSA C22.2 No. 213-17 Ed. 3
– UL 60079-0 Ed. 7, CSA C22.2 No. 60079-0 Ed. 4
– UL 60079-7 Ed. 5, CSA C22.2 No. 60079-7 Ed. 2
Canada
• ICES-003:2016 (Class A)
• Hazardous Locations
– CSA C22.2 No. 213-15
– CAN/CSA-C22.2 NO. 60079-0:15, Class I,
Zone 2
– CAN/CSA-C22.2 NO. 60079-15:12
• WEEE & Battery Regulations
Environmental
Hot Temperature: IEC 60068-2-2:2007 Test Be
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.
COPYRIGHT© 2003-2026 Copyrighted
Phone(WeChat/Whatsapp)
+086-181 4410 0983
No 1134 Jimei North Road,
Hong Kong Office:
Guan Tang District, Hong Kong,