GE MIGII Legacy Generator Protection System
ModulAr MIcroProcESSor FAMIly An economical choice for standard digital relaying applications
KEy BEnEFItS • Ease of use and installation - same front panel programming, common cutout
• Follow technology evolution - Flash memory for product field upgrades
• Low priced scalable options - event reports, waveform capture, recloser, breaker fail
• Reduce troubleshooting and maintenance cost - Event reports, waveform capture
• Design flexibility - Easy to use programming logic APPlIcAtIonS
• Asset monitoring - Breaker health, and breaker failure protection
• Access to information - Modbus RTUTM communications
• AC/DC power supply
• Easy access via front panel keypad or communication link
APPlIcAtIonSFeeder protection • Main protection for small generators and motors • Backup/Auxiliary protection for transformers, motors, generators and busbars • Overload protection FEAturES • Automatic transfer equipment • Load shedding and restoration schemes • Backup directional overcurrent protection • Reverse power protection • Synchrocheck
ProtEctIon PHASE tIME oVErcurrEnt Pickup level: 10 – 240% of CT rating curve shapes: Definite time, inverse, very inverse, extremely inverse, custom time multiplier: 0.05 – 2.00 in steps of 0.01 definite time: Up to 99.99 sec (10 msec steps) Accuracy: level: ±3% in the complete range time: Greater of ±3% or ±25 ms Ground tIME oVErcurrEnt Pickup level: 10 – 240% of CT rating curve shapes: Definite time, inverse, very inverse, extremely inverse, custom time multiplier: 0.05 – 2.00 in steps of 0.01 definite time: Up to 99.99 sec (10 msec steps) Accuracy: level: ±3% in the complete range time: Greater of ±3% or ±25 ms PHASE InStAntAnEouS Pickup level: 10 – 3000% of CT rating definite time: Up to 99.99 sec (10 msec steps) Accuracy: level: ±3% in the complete range time: Greater of ±3% or ±25 ms Ground InStAntAnEouS Pickup level: 10 – 3000% of CT rating definite time: Up to 99.99 sec (10 msec steps) level: ±3% in the complete range time: Greater of ±3% or ±25 ms Ground dIrEctIonAl torque angle:-90°, +90° (1° steps) direction: Forward/back (rew) loss of voltage polarization logic: Enable/disable ISolAtEd Ground dIrEctIonAl (MIn oPtIon S) Voltage pickup levels: Vh 2 – 70 V in steps of 0.01 V Vi 2 – 70 V in steps of 0.01 V current pickup levels: I low 5 – 400 mA in steps of 1 mA I hi 5 – 400 mA in steps of 1 mA definite time: 0 – 99.99 sec in steps of 10 msec Instantaneous trip deviation time: 0 – 99.99 sec in steps of 100 msec torque angle:-90°, +90° (1° steps) PEtErSEn coIl Ground dIrEctIonAl Voltage pickup levels: Vh 2 – 45 V in steps of 0.1 V current pickup levels: I low 5 – 100 mA in steps of 1 mA real power pickup levels: 10 – 4500 mW in steps of 0.1 mW definite time: 0.03 – 3 sec in steps of 10 msec Instantaneous trip deviation time: 1 – 10 sec in steps of 100 msec torque angle:-90, +90 (0.01 steps) dIrEctIonAl rEVErSE PoWEr Power pickup level: 0.01 – 0.99 x Rated MW time delay: 0.2 – 120 seconds in steps of 0.1 Block from online: 0 – 5,000 sec. dIrEctIonAl loW ForWArd PoWEr Power pickup level: 0.01 – 0.99 x Rated MW time delay: 0.2 – 120 seconds in steps of 0.1 Block from online: 0 – 15,000 sec. loSS oF EXcItAtIon circle 1 diameter: 2.5 – 300 ohm circle 1 offset: 2.5 – 150 ohm circle 1 trip delay: 0.1 – 10 sec circle 2 diameter: 2.5 – 300 ohm circle 2 offset: 2.5 – 150 ohm circle 2 trip delay: 0.1 – 10 sec tHErMAl IMAGE unIt tap current: 10 – 240% of CT rating cool rate: t1 3 – 600 min t2 1 – 6 x T1 K 1 – 1.2 Alarm level: 70 – 100% PHASE undErVoltAGE Pickup level: 2.0 to 60 V or 10 to 250 V in steps of 0.1 (depending on model) curve shapes: Definite time time delay: 0.0 to 600 sec in steps of 0.01 Accuracy: level: ±3% over the complete range time: Greater of ±3% or ±25 ms PHASE oVErVoltAGE Pickup level: 2.0 to 60 V or 10 to 250 V in steps of 0.1 (depending on model) curve shapes: Definite time time delay: 0.0 to 600 sec in steps of 0.01 Accuracy: level: ±3% over the complete range time: Greater of ±3% or ±25 ms Ground oVErVoltAGE Pickup level: 2.0 – 60 V or 10 – 250 V in steps of 0.1 (depending on model) curve shapes: Definite time time delay: 0.0 to 600 sec in steps of 0.01 Accuracy: level: ±3% over the complete range time: Greater of ±3% or ±25 ms
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.