GE F650 Digital Bay Controller
The Multilin F650 has been designed for the protection, control and automation of feeders or related applications. The Multilin F650 feeder protection relay provides high speed protection and control for feeder management and bay control applications, and comes with a large LCD and single line diagrams that can be built for bay monitoring and control for various feeder arrangements including ring-bus, double breaker or for breaker and half.
Key Benefits
Comprehensive and flexible protection and control device for feeder applications
Increased system uptime and improved stability with load shedding and transfer schemes
Advanced automation capabilities for customized protection and control solutions
Human machine interface (HMI) with graphical LCD, programmable buttons, and easy keys for selecting setting menus, and submenus
Reduced replacement time with modular draw-out construction
Reduced troubleshooting time and maintenance costs with IEEE 1588 (PTP), IRIG-B and SNTP time synchronization (configuration of two different SNTP masters), event reports, waveform capture, and data logger
Simplified system integration with communications supporting serial and Ethernet interfaces as well as multiple protocols
Embedded IEC® 61850 protocol (and support for edition 2), IEC 60870-5-103/104, IEC 62439/PRP/HSR, IEEE 802.1D/RSTP
Proven interoperability and KEMA 61850 Edition 2 certified
Applications
Primary or back-up protection and control for feeders on solidly grounded, high impedance grounded or resonant grounded systems
Bus blocking/Interlocking schemes
High-speed fault detection for arc flash
Throw over schemes (bus transfer scheme applications)
Load shedding schemes based on voltage and frequency elements
Distributed Generation (DG) interconnect protection, including active and passive anti-islanding
System requirements
The relay front panel or the EnerVista 650 Setup software can be used to communicate with the relay. The software
interface is the preferred method to edit settings and view actual values because the computer monitor can display more
information.
The minimum system requirements for the EnerVista 650 Setup software are as follows:
• Pentium® 4 (Core Duo recommended).
• Windows® XP with Service Pack 2 (Service Pack 3 recommended), Windows 7, Windows 8 or Windows 10
• 1 GB of RAM (2 GB recommended).
• 500 MB free hard drive space (1 GB recommended).
• 1024 x 768 display (1280 x 800 recommended).
• RS232 and USB serial and/or Ethernet port for communications with the relay.
---------------------------------
GE Panametrics 710-1428 Moisture Target Ctrl/Display Panel 7101428 Panel Only |
GE PANAMETRICS MTS5-3A10-10 SERIES 5 MOISTURE TARGET -FREE SHIPPING- |
GE Panametrics ISX878 Flowmeter ISX878-1-LP-CG -0-0-1 General Electric Flow Meter |
GE PANAMETRICS Model 25 HPV 25DL Ultrasonic Velocity Gauge |
GE Panametrics AT 868 AquaTrans Flowmeter Case Box Enclosure Replacement Unit |
GE Panametrics 8R0470 flowmeter transducer 0.5 MHZ , pair 2 pcs |
Panametrics Model 22 Ultrasonic Thickness Gage - Olympus GE NDT Inspection Bulk |
Battery for GE 200-081 Panametrics PT878 Flowmeter Portable Flowmeter 6V Ni-MH |
Panametrics P170752-R4M2-1 /2 GE Sensor Probe Kit P170752R4M212 (Pack of 4) |
GE Panametrics M2LR Moisture Probe in Factory Case |
GE Panametrics C-RS-402 High Performance Transducers |
Dual RG174 Cable BNC 10~131FT For GE Panametrics PT868 PT878 Portable Flow Meter |
PAIR OF GE PANAMETRICS PROBE M2L MOISTURE SENSORS |
GE PANAMETRICS C-PT-20-H-B-00 -0, Transducer Pair, -20 to 210C 2MHz - NEW |
BNC to BNC Cable For Ultrasonic NDT Olympus GE Panametrics MISTRAS RG316 2~10M |
1~16' BNC to Subvis 10-32 NDT Cable For GE Panametrics Krautkramer Flaw detector |
GE Panametrics Moisture Monitor Series 35 MMS35-221-1-10 0 |
Twinax RG174 Cable TNC 10~131FT For GE Panametrics Portable PT900 Flow Meters |
GE Panametrics Moisture Probe M2LW-00-010-0 |
GE PANAMETRICS PM880 PORTABLE HYGROMETER PM880-361E |
GE Panametrics TransPort PT878 PORTABLE LIQUID FLOWMETER with C-RS-402 |
GE PANAMETRICS 703-1141 rev A card |
GE SENSING PANAMETRICS UC-F-R-24-0-0 |
1x GE Panametrics 705-1326-01 Zirconium Oxide Oxygen Sensor Assembly |
Olympus GE Panametrics SnakeEye Industrial Videoscope Borescope |
GE Panametrics M Series Moisture Probe MS30 |
GE Panametrics TMO2D Display and Control Module |
GE TMO2D-122-21 PANAMETRICS DISPLAY AND CONTROL MODULE (JJ4) |
GE PANAMETRICS AT868W-2-1-1-2 AQUA TRANS FLOWMETER |
GE Sensing CRL-10-MB Ultrasonic Flow Safe Transducer Module Panametrics Unit |
Dust Cap Cover Boot for Microdot Connector Ultrasonic Panametrics Krautkramer GE |
NEW GE PANAMETRICS 15/.25 F=15" PTF 288669 , V313 |
Krautkramer Branson USN 52 Ultrasonic Flaw Detector, , Tested, USS |
NEW LECTRODRYER GE PANAMETRICS MTS5-321-1S DEW POINT MONITOR |
GE PANAMETRICS PM880 PORTABLE HYGROMETER WITHOUT BATTERY WORKING |
Kastar Ni-MH Battery 6V 3000mAh for GE Portable Flowmeter Panametrics TEB200081 |
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.
COPYRIGHT© 2003-2025 Copyrighted
Phone(WeChat/Whatsapp)
+086-181 4410 0983
No 1134 Jimei North Road,
Hong Kong Office:
Guan Tang District, Hong Kong,