ABB EasyLine EL3000 Continuous Gas Analyzers
Measuring technology (analyzers) The following analyzers are available for selection:
Uras26 infrared photometer for the measurement of infrared-active gas components e.g. CO, NO, SO2
Limas23 ultraviolet photometer for the measurement of NO, NO2 and SO2
Magnos206 oxygen analyzer for the measurement of O2 in process gas or in N2
Magnos27 oxygen analyzer for the measurement of O2 in flue gas or in N2
ZO23 trace oxygen analyzer for the measurement of O2 in pure gases (N2, CO2, Ar)
Caldos27 thermal conductivity analyzer for the measurement of binary gas mixtures with different thermal conductivity e.g. Ar in O2, H2 in Ar, CH4 in N2 Fidas24 flame-ionization detector for the measurement of hydrocarbons
Electrochemical oxygen sensor for the measurement of O2 Magnos206 can also be used in combination with Uras26 or Limas23. Magnos27 and Caldos27 can also be used in combination with Uras26. Fidas24 and ZO23 cannot be used in combination with one of the other analyzers. Only one ZO23 can be installed in the gas analyzer. The electrochemical oxygen sensor can only be used in combination with Uras26 or Limas23. Two electrochemical oxygen sensors can be used in combination with Uras26 with separate gas paths (only in model EL3020). Each analyzer has one physical measurement range per sample component. A section of the physical measurement range can be mapped to the current output (analog output) by on-site configuration. Calibration is always executed in the physical measurement range. The permissible measurement range limits are given by the specification of the smallest and largest measurement ranges for the individual analyzers. A total of up to five measurement components can be measured with one gas analyzer.
Version for measurement of flammable gases In the version with gas lines and connectors made of stainless steel the gas analyzer (Models EL3020 and EL3040) with Uras26, Magnos206, Caldos27 and ZO23 (concentration max. 100 ppm) is suitable for measuring flammable gases in general purpose environment. In model EL3040, housing purge with nitrogen (ZO23: with air) must be provided. The positive pressure in the sample gas feed path may not exceed a maximum value of 100 hPa in normal operation and a maximum value of 500 hPa in the event of a fault. The special requirements must be observed (see operator’s manual).
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.