Technical data
Mains supply volt. 2 30...1,200 V,
+/–10 %, 3~
Frequency 50...60 Hz, +/–5
Hz
Electronics supply 115...230 V,
–15 % / +10 %, 1~
DC Output current 2 0...5,200 A
Overload capability 2 00 %
Ambient conditions
Ambient temperat. 0° ... +40° C
40° ... 55°C with
reduction
Storage temperat. –40° ... +55° C
Transport temper. –40° ... +70° C
Relative humidity 5 ... 95 %, not
condensing
(max. 50 % betw.
0°...5° C)
Pollution degree Class 2
Protection class IP 00
Altitude < 1,000 m height
above sea level:
nominal Current
> 1,000 m height
above sea level:
with reduction
I/O
Digital inputs: 8 standard, up to
14 optional
Digital outputs: 8 standard, up
to 12 optional
Analog inputs: 4 standard +/–
10 V; 0/2…10 V, up to 8 optional
+/ 2 0 mA; 0/4…20 mA
Analog outputs: 3 standard (1x
Iact) +/-10 V; 0/2…10 V, up to 7
optional –20 mA; 0/4…20 mA
PC-Tools
DriveWindow Light: free of
charge with every converter,
Standard RS232 PC-connection
DriveWindow: Real-time optical
connection
ControlBuilder DCS800:
IEC61131 programming tool
DriveSize: Converter- and motor
dimensioning
Maintenance / Diagnosis
Remote diagnosis with any
Internet-PC worldwide
• with internet browser / internet
explorer
• or with DriveWindow full drive
control via OPC
Adaptive Programming
pre-defined drive-specific
function blocks, e.g.
• Free process controller (PIController)
• I/O- and digital Operations
With control panel or PC-Tool, no
need for additional hardware
Speed Feedback
EMF
Analogue tacho
Encoder
2nd Encoder possible (RTAC)
Communication
Serial communication
• Ethernet • Profibus
• CANopen • DeviceNet
• ControlNet • DDCS
• Modbus
• CS31 • AF100
• Selma2
Industrial IT© enabled
DCSLink Peer-to-Peer
• up to 800 kBaud, < 2.5 ms
• Master-Follower
• Armature-fieldconverter
• Free selectable data
High Current Solutions
• 12-pulse up to 20,000 A, serial
and parallel
• Hard parallel and sequential
• up to 1,500 V
Protections
Speed feedback monitoring •
Temperature • Overload • Over
speed • Motor stalled • Motor
over current • Motor over voltage
• Field over current • Field over
voltage • Minimum field current
• Zero speed • Armature current
ripple • Mains over- and under
voltage
Integrated IEC 61131-PLC
• Open standard programming
tool ControlBuilder DCS800
• Support of all five IEClanguages
• Drive-specific function blocks
• Saving of program and source
in Memory Card
• Online debugging and forcing
DCS800-S01-0020-04/05...
DCS800-S02-0025-04/05
D1 - no fan
DCS800-S0x-0045-04/05...
DCS800-S0x-0140-04/05
D1 1 115 or 230 VAC
DCS800-S0x-0180-04/05...
DCS800-S0x-0260-04/05
D2 1 115 or 230 VAC
DCS800-S0x-0315-04/05...
DCS800-S0x-0350-04/05
D3 1 115 or 230 VAC
DCS800-S0x-0405-04/05...
DCS800-S0x-0520-04/05
D3 2 115 or 230 VAC
DCS800-S0x-0610-04/05...
DCS800-S0x-0820-04/05
D4 3 230 VAC
DCS800-S0x-0610-04/05...
DCS800-S0x-0820-04/05
D4
Pluscode S171
3 115 VAC
DCS800-S0x-0900-04/05...
DCS800-S0x-1000-04/05
D4 3 230 VAC
DCS800-S0x-0900-04/05...
DCS800-S0x-1000-04/05
D4
Pluscode S171
3 115 VAC
Technical catalogue (3ADW000192)
as comprehensive information to engineer complete DC
drive systems.
Hardware manual (3ADW000194)
as detailed information, with all important particulars about
the individual components, like module dimensions, electronic
boards, fans and auxiliary components.
Information for mechanical and electrical installation are
also included.
Firmware Manual (3ADW000193)
detailed information with all important issues about firmware
and setting of parameters. The manual includes information
for start-up and maintenance of the entire drive, in detailed
form.
This manual also includes Fault and Alarm codes and information
for trouble shooting.
Service Manual (3ADW000195)
for maintenance and repair of the converters.
Applications
DCS800 DC Drive can include application software e.g.
cranes, winders. In such case following procedures and
assistants can be blocked or not completed. Please check
for further documentation and manuals (check parameter
4.03, 83.01).
Additional information about applications (e.g. 12-pulse)
and technical accessories (e.g. Hardware extension or
Field bus interfaces) are handled by separate manuals. See
table DCS800 Drive manuals.
3ADT220129R0002 DCS-CP-P Control Panel for DCS800
1 3ADT220071R0006 CDP312RD Rev.G Possible via SDCS-COM-8 only
1 3ADT200005R0001 SDCS-DSL-4 (+S199)
1 3ADT220134R0001 SDCS-COM-81 (+L508), 10 Mbd (e.g. AC 800M)
1 3ADT220134R0002 SDCS-COM-82 (+L509), 5 Mbd (fieldbus)
1 3AFE64606859 RPBA-01 (+K454)
1 3AFE64606891 RDNA-01 (+K451)
1 3AFE64606778 RMBA-01 (+K458)
1 3AFE64606905 RCAN-01 (+K457)
1 3AFE64751701 RCNA-01 (+K462)
1 3AFE64751727 RETA-01 (+K466)
1 3AUA0000045102 RECA-01 (+K469)
2 3AFE64606841 RAIO-01 (+L500)
2 3AFE64606816 RDIO-01 (+L501)
1 3AFE64610805 RTAC-01 (+L502)
1 3AFE68654947 RTAC-03 (+L517)
1 3AFE68286778 AIMA-01
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.
COPYRIGHT© 2003-2025 Copyrighted
Phone(WeChat/Whatsapp)
+086-181 4410 0983
No 1134 Jimei North Road,
Hong Kong Office:
Guan Tang District, Hong Kong,