GE Grid Solutions Multilin 469 SR469-P5-HI-A20-E-H
The Multilin™ 469 Motor Protection System, a member of the SR family of relays, provides protection,
control, simplified configuration and advanced communications in a cost effective industry leading
draw-out construction. Designed for medium voltage motors, the 469 delivers advanced protection with
customizable overload curves and single CT differential protection for added flexibility. The 469 also
provides simplified configuration using the Motor Settings Auto-Configurator, providing a quick and easy
set-up of motor parameters. Coupled with advanced protection and diagnostics, the 469 provides users
the flexibility of multiple communication protocols allowing integration into new and existing control
networks.
Key Benefits
• Comprehensive motor protection plus voltage dependant overload curves, torque metering and
protection, broken rotor bar protection
• Most advanced thermal model - Including multiple RTD inputs for stator thermal protection
• Minimize replacement time - Draw-out construction
• Complete asset monitoring - Temperature, Analog I/O, full metering including demand & energy
• Improve uptime of auxiliary equipment - Through I/O monitoring
• Reduce troubleshooting time and maintenance costs - Event reports, waveform capture, data logger
• Built in simulation functions simplify testing and commissioning
• Cost Effective Access to information - Through standard RS232 & RS485 serial ports, and optional Ethernet and DeviceNet Ports
• Field upgradable firmware and settings
• Optional Conformal coating for exposure to chemically corrosive or humid environments
Motor Thermal Model
The primary protective function of the 469 is the
thermal model with six key elements:
• Overload Curves
• Unbalance Biasing
• Hot/Cold Safe Stall Ratio
• Motor Cooling Time Constants
• Start Inhibit and Emergency Restart
• RTD Biasing
Ground Fault
This function is designed to protect motors
against phase to ground faults.
There are two dedicated ground current inputs
in the relay, which support the following types
of ground current detection.
• Core balance (Zero sequence) current
transformer.
• Core balance (Zero sequence) 50:0.025 A
(sensitive) current transformer.
• Residual connection of phase current
transformers.
The function is equipped with an overreach filter,
which removes the DC component from the
asymmetrical current present at the moment a
fault occurs, or a motor starts. Two pickup levels
( trip and alarm) with individual time delays are
available for ground fault detection.
A trip Backup feature is also available as part
of this function. The operational principal of
Ground Fault Trip Backup is the same as of
Short Circuit Trip Backup.
Reactive Power
This element is used in applications where the
reactive power limit is specified.
Underpower
Used to detect loss of load.
Reverse Active Power
Useful to detect conditions where the motor
can become a generator.
Overtorque
This element is used to protect the driven load
from mechanical breakage.
Current Unbalance
In addition to thermal model biasing current
unbalance is available in the 469 relay as an
independent element with 2 pickup levels and a
built-in single phasing detection algorith
Keypad and Display
The 469 has a keypad and 40 character display
for local monitoring and relay configuration
without the need for a computer. Up to 20
user-selected default messages can be
displayed when inactive. In the event of
a trip, alarm, or start block, the display
will automatically default to the pertinent
message and the Message LED indicator will
flash.
Event Recorder
The event recorder stores motor and system
information with a date and time stamp each
time a system event occurs. Up to 256 events
are recorded.
Oscillography
The 469 records up to 64 cycles with 12 samples
per cycle of waveform data for 10 waveforms
(Ia, Ib, Ic, Ig, Diffa, Diffb, Diffc, Va, Vb, Vc) each
time a trip occurs. The record is date and time
stamped.
Viewpoint Monitoring
Viewpoint Monitoring is a powerful yet simpleto-
use monitoring and data recording of
small systems. Viewpoint Monitoring provides
a complete HMI package with the following
functionality:
• Plug-&-Play Device Monitoring
• Single-Line Monitoring & Control
• Annunciator Alarming
• Trending Reports
• Automatic Event Retrieval
• Automatic Waveform Retrieval
SR469-P5-HI-A20
SR469-P5-HI-A20-E
SR469-P5-HI-A20-E-H
SR469-P5-HI-A20-H
SR469-P1-HI-A20-H
SR469-P1-LO-A1-D-H
SR469-P1-LO-A1-T-H
SR469-P1-LO-A1-E-H
SR469-P5-HI-A20-D-H
SR469-P5-HI-A20-T-H
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.
COPYRIGHT© 2003-2024 Copyrighted
Phone(WeChat/Whatsapp)
+086-18144100983
No 1134 Jimei North Road, Jimei District
Hong Kong Office: