MVI56-MCM Modbus Master/Slave Communication Module
Modbus Master/Slave
Communication Module
MVI56-MCM
Applications using the Modbus Communication Module
can be found in many industrial sectors and in the
following applications:
• Foreign device data concentrator
• Pipelines and offshore platforms
• Food processing
• Mining
• Pulp and paper
• SCADA communications
How to Contact Us: Sales and Support
All ProSoft Technology products are backed with
unlimited technical support. Contact our worldwide
Technical Support team directly by phone or email:
Asia Pacific
+603.7724.2080, asiapc@prosoft-technology.com
Languages spoken include: Chinese, Japanese, English
Europe – Middle East – Africa
+33 (0) 5.34.36.87.20, support.EMEA@prosofttechnology.
com
Languages spoken include: French, English
North America
+1.661.716.5100, support@prosoft-technology.com
Languages spoken include: English, Spanish
Latin America (Sales only)
+1.281.298.9109, latinam@prosoft-technology.com
Languages spoken include: Spanish, English
MVI56-MCM
The MVI56 Modbus Master/Slave
Communication Module allows Rockwell Automation
ControlLogix processors to interface easily with other
Modbus protocol compatible devices.
Compatible devices include not only Modicon PLCs
(which all support the Modbus protocol) but also a wide
assortment of end devices. The module acts as an
input/output module between the Modbus network and
the Rockwell Automation backplane. The data transfer
from the processor is asynchronous from the actions on
the Modbus network. A 5000-word register space in the
module exchanges data between the processor and the
Modbus network.
Features and Benefits
The inRAx Modbus Master/Slave Communications
module is designed to allow ControlLogix processors to
interface easily with Modbus protocol-compatible
devices and hosts.
The MVI56-MCM module acts as an input/output module
between the Modbus network and the Rockwell
Automation backplane. The data transfer from the
ControlLogix processor is asynchronous from the actions
on the Modbus network. A 5000-word register space in
the module exchanges data between the processor and
the Modbus network.
Many host SCADA packages support the Modbus
protocol, while devices commonly supporting the
protocol include several PLCs, as well as many other
third party devices in the marketplace. (For a partial list
of devices that speak Modbus, please visit the ProSoft
Tested section of the ProSoft Technology web site).
General Specifications
• Single Slot – 1756 backplane compatible
• Local or remote rack
• The module is recognized as an Input/Output
module and has access to processor memory for
data transfer between processor and module
• Ladder Logic is used for data transfer between
module and processor.
• Configuration data obtained through user-defined
ladder. Sample ladder file included
Functional Specifications
Some of the general specifications include:
• Support for the storage and transfer of up to 5000
registers to/from the ControlLogix processor's data
files
• Module memory usage that is completely user
definable
• Two ports to emulate any combination of Modbus
master or slave device
• Supports Enron version of Modbus protocol for
floating point data transactions.
Slave Specifications
The MVI56-MCM module accepts Modbus function code
commands of 1, 2, 3, 4, 5, 6, 8, 15, 16, 17, 22 and 23
from an attached Modbus master unit. A port configured
as a Modbus slave permits a remote master to interact
with all data contained in the module. This data can be
derived from other Modbus slave devices on the
network, through a master port, or from the ControlLogix
processor.
Master Specifications
A port configured as a virtual Modbus master device on
the MVI56-MCM module actively issues Modbus
commands to other nodes on the Modbus network. One
hundred (100) commands are supported on each port.
Additionally, the master ports have an optimized polling
characteristic that polls slaves with communication
problems less frequently. The ControlLogix processor
can be programmed to control the activity on the port by
actively selecting commands from the command list to
execute or issuing commands directly from the ladder
logic.
Additional Products
ProSoft Technology offers a full complement of
hardware and software solutions for a wide variety of
industrial communication platforms. Compatible products
in the inRAx product line also include:
Modbus Communication Module with Reduced Data
Block (MVI56-MCMR)
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.
COPYRIGHT© 2003-2024 Copyrighted
Phone(WeChat/Whatsapp)
+086-18144100983
No 1134 Jimei North Road, Jimei District
Hong Kong Office:
Guan Tang District, Hong Kong,